Skip to content

Running Software

Sam Bilbow edited this page Dec 10, 2022 · 4 revisions

Prerequisites

  1. You have all the Software Requirements
  2. The ambisonic microphone is plugged in, powered by 48V and selected in Max's audio options
  3. The wearable IMU / bone conduction headphones are on, connected to the host computer, and transmitting data.
  4. The bone conduction headphones are selected as the audio output in Max's audio options

Max 8 patch

  1. Open area~.maxpat in Max 8
  2. Connect to the appropriate serial device
    1. Leave presenter view (cmd-option-e)
    2. Open [p serial]
    3. Enter edit mode (cmd-e)
    4. Change [serial b 115200] to reflect your serial device's index
    5. Leave edit mode (cmd-e)
    6. Close [p serial]
    7. Enter presenter view (cmd-option-e)
  3. Set up the patch audio settings
    1. Turn on the Stereo Out [ezdac~]
    2. Loop Level [slider]
    3. Grain Level [slider]
    4. Notification Level [slider]
    5. Main Level [slider]
    6. Check the RØDE Plugin to ensure signal from the microphone is being received
    7. (optional) If not using a microphone, place an ambisonic file called test.wav in project root folder, and toggle on Use Test Track [x]
  4. Turn on the function toggles
    1. [x] Gestures
    2. [x] Visualiser (optional)
    3. [x] Head Tracking
      1. The ambimonitor on the left side of the patch should now show two points rotating as your head moves