  • BEFORE you start - Set MTU - 1700 or 9000 on the distributed switch on vCenter > Network section

  • Download the NSX-T Manager from VMWare portal

  • Ensure the ESXi hosts are upgraded to the 6.7 U3 (use upgrade manager to upgrade the hosts)

  • Create a distributed switch dvSwitch and assign the vmnic1 (Use vcenter-terraform for HOMELAB) for all the hosts that are part of this switch

  • Import the NSX-T manager using govc (Use ../deploy-nsx/govc-deploy)

    • Create a file govc-env and paste the following contents into it
    export GOVC_INSECURE=1
    export GOVC_URL=vcenter.homelab.io
    export GOVC_USERNAME=automation@homelab.io
    export GOVC_PASSWORD=VMware1!
    export GOVC_DATACENTER=HOMELAB
    export GOVC_DATASTORE=COMMON_STORAGE
    export GOVC_NETWORK="VM Network"
    export GOVC_RESOURCE_POOL=/HOMELAB/host/MANAGEMENT/Resources/NSX_RP
    export GOVC_HOST=esxi-1.homelab.io
    
    • Create a file called nsx-appliance.json with the following contents
    {
      "Deployment": "medium",
      "DiskProvisioning": "flat",
      "IPAllocationPolicy": "dhcpPolicy",
      "IPProtocol": "IPv4",
      "PropertyMapping": [
        {
          "Key": "nsx_passwd_0",
          "Value": "VMware1!"
        },
        {
          "Key": "nsx_cli_passwd_0",
          "Value": "VMware1!"
        },
        {
          "Key": "nsx_cli_audit_passwd_0",
          "Value": "VMware1!"
        },
        {
          "Key": "nsx_cli_username",
          "Value": "admin"
        },
        {
          "Key": "nsx_cli_audit_username",
          "Value": "audit"
        },
        {
          "Key": "extraPara",
          "Value": ""
        },
        {
          "Key": "nsx_hostname",
          "Value": "nsx.homelab.io"
        },
        {
          "Key": "nsx_role",
          "Value": "NSX Manager"
        },
        {
          "Key": "nsx_gateway_0",
          "Value": "172.16.0.1"
        },
        {
          "Key": "nsx_ip_0",
          "Value": "172.16.0.61"
        },
        {
          "Key": "nsx_netmask_0",
          "Value": "255.255.254.0"
        },
        {
          "Key": "nsx_dns1_0",
          "Value": "172.16.0.30,172.16.0.31"
        },
        {
          "Key": "nsx_domain_0",
          "Value": ""
        },
        {
          "Key": "nsx_ntp_0",
          "Value": "ntp.homelab.io"
        },
        {
          "Key": "nsx_isSSHEnabled",
          "Value": "True"
        },
        {
          "Key": "nsx_allowSSHRootLogin",
          "Value": "True"
        },
        {
          "Key": "mpIp",
          "Value": ""
        },
        {
          "Key": "mpToken",
          "Value": ""
        },
        {
          "Key": "mpThumbprint",
          "Value": ""
        },
        {
          "Key": "mpNodeId",
          "Value": ""
        },
        {
          "Key": "mpClusterId",
          "Value": ""
        }
      ],
      "NetworkMapping": [
        {
          "Name": "Network 1",
          "Network": "VM Network"
        }
      ],
      "MarkAsTemplate": false,
      "PowerOn": true,
      "InjectOvfEnv": false,
      "WaitForIP": false,
      "Name": "nsx-manager"
    }
    
    • Source the govc-env file and then execute govc import.ova -options=nsx-appliance.json nsx-unified-appliance-3.0.2.0.0.16887203.ova
  • Once the NSX manager is up and running, navigate to the nsx manager console and login

  • Generate a CSR and self signed certificate, navigate to System > Certificates

  • Update the nsx manager certificate using the curl command

    • curl -u "admin:VMware1!" -X POST --insecure "https://nsx.homelab.io/api/v1/node/services/http?action=apply_certificate&certificate_id=52bba154-3803-4e8e-b732-6a8c191a370b"
  • Add the nsx manager license

  • Update the Gloabl MTU on NSX-Manager to 9000, System > Fabric > Settings

  • Register compute manager

  • In NSX-T 3.x, NSX Manager and NSX controller are bundled together

  • Create 2 transport zones

    NAME SWITCH
    switch-overlay switch-overlay
    switch-vlan switch-vlan

  • Create a Profile

    • Name: nsx-esxi-uplink-hostswitch-profile
    • Teamings Name: Default Teaming | Active Uplinks: uplinks-1
    • Transport VLAN: 3000
    • MTU: BLANK

  • Create a TEP-IP-POOL by going to Networking > IP Address Pools > IP Address Pools

    • TEP-IP-POOL | 172.16.100.1-172.16.100.254 | 172.16.100.0/24 (CIDR)

  • Create the Load Balancer Active Monitors, Networking > Load Balancing > Monitors > Add Active Monitors

    TYPE NAME MONITORING PORT
    TCP ROUTERS 8080
    TCP DIEGO_BRAINS 2222
    TCP ISTIO_ROUTERS 8080
    TCP TKGI_API 9021

  • Create the Transport Node Profile by clicking on Fabric > Profiles > Transport Node Profiles

    • Name: host-transport-node-profile
    • Type N-VDS
    • Mode: Standard
    • Name: switch-overlay
    • Transport Zone: switch-overlay
    • Uplink Profile: nsx-esxi-uplink-hostswitch-profile
    • IP Assignment: Use IP Pool
    • IP Pool: TEP-IP-POOL
    • Uplinks: uplink-1 (active): vmnic1

OR

  • Create the Transport Node Profile by clicking on Fabric > Profiles > Transport Node Profiles

    • Name: host-transport-node-profile
    • Type VDS
    • Name: vCenter dvSwitch
    • Transport Zone: switch-overlay switch-vlan
    • Uplink Profile: nsx-esxi-uplink-hostswitch-profile
    • IP Assignment: Use IP Pool
    • IP Pool: TEP-IP-POOL
    • Uplinks: uplink-1 (active): uplink1

  • Click on System > Fabric > Nodes > Edge Transport Nodes > Add Edge VM

    • Create the edge node, of large form factor. Load balancers need minimum of large edge node
    • Name it nsx-edge with the hostname nsx-edge.homelab.io
    • Use password VMware1!
    • Allow SSH Login & Allow Root SSH Login - true
    • Compute Manager: vCenter
    • Cluster: WORKLOAD
    • Resource Pool: NSX
    • Datastore: MANAGEMENT_STORAGE
    • Assign a static IP to the edge 172.16.0.62/22 and gateway is 172.16.0.1
    • Select the network as VM Network for all the 4 interfaces

    • Assign the overlay transport zone (East-West)
      • Edge Switch Name: switch-overlay
      • Transport Zone: switch-overlay
      • Uplink Profile: nsx-edge-single-nic-uplink-profile
      • IP Assignment: Use IP Pool
      • IP Pool: TEP-IP-POOL
      • Uplinks: uplink-1 (active) | Virtual NICs: fp-eth0 | EDGE-VTEP-PG
      • Physical NICs: vmnic1 - uplink-1

    • Assign the vlan transport zone (North-South)
      • Edge Switch Name: switch-vlan
      • Transport Zone: switch-vlan
      • Uplink Profile: nsx-edge-single-nic-uplink-profile
      • Uplinks: uplink-1 (active) | Virtual NICs: fp-eth1 | EDGE-UPLINK-PG
      • Physical NICs: vmnic1 - uplink-1

  • Create a new edge cluster edge-cluster

  • Click on System > Fabric > Nodes > Host Transport Nodes > vCenter > WORKLOAD

    • Configure NSX and select the host-transport-node-profile

  • Final view of vSphere Network after terraform


NOTE: choose vmnic1 as vmnic0 is already assigned to the distributed switch common_dvPortGroup

Validate this setting on nsx-edge before moving on

N-VDS Type Uplink Profile IP Allocation Virtual Nics
nsx-overlay-transportzone nsx-edge-single-nic-uplink-profile Use IP Pool (TEP-IP-POOL) fp-eth0
nsx-vlan-transportzone nsx-edge-single-nic-uplink-profile - fp-eth1

BELOW THIS IS ALL TERRAFORMED

  • Create Tier-0 Gateway by clicking on Networking > Tier-0 Gateway > Add Gateway

    • Name: ROUTER-T0
    • HA Mode: Active Standby
    • Edge Cluster: edge-cluster
    • Failover Mode: Non-Preemptive
  • Create Tier-1 Gateway by clicking on Networking > Tier-1 Gateway > Add TIER-1 Gateway INFRASTRUCTURE-T1 and enable Router-Advertisement for:

    • All Static Routes
    • All Connected Segments & Service Ports
    • All LB VIP Routes
  • Create Tier-1 Gateway by clicking on Networking > Tier-1 Gateway > Add TIER-1 Gateway DEPLOYMENT-T1 and enable Router-Advertisement for:

    • All Static Routes
    • All Connected Segments & Service Ports
    • All LB VIP Routes
  • Create Tier-1 Gateway by clicking on Networking > Tier-1 Gateway > Add TIER-1 Gateway SERVICES-T1 and enable Router-Advertisement for:

    • All Static Routes
    • All Connected Segments & Service Ports
    • All LB VIP Routes
  • Create Segments (logical switches), Networking > Segments

Name Uplink & Type Subnet Transport Zone VLAN
INFRASTRUCTURE INFRASTRUCTURE-T1 192.168.10.1/26 switch-overlay -
DEPLOYMENT DEPLOYMENT-T1 192.168.12.1/23 switch-overlay -
SERVICES SERVICES-T1 192.168.14.1/23 switch-overlay -
UPLINKS - - switch-vlan 0
  • Select the ROUTER-T0 and then Edit > Interfaces > External and Service Interfaces > Configuration > Router Ports > Add

    • Name: UPLINK-TO-PYHSICAL
    • MTU: 1600
    • Transport Node: edge-tn
    • Logical Switch: UPLINKS
    • Logical Switch Port: Attach to new switch port
    • IP Address/mask: 172.16.0.28/23
  • Select the ROUTER-T0 and then click Edit > Routing > Static Routes > Add

    • Network: 0.0.0.0/0
    • Next Hop: 172.16.0.1
    • Distance: 1
  • Configuring NAT rules, select the Gateway ROUTER-T0 and then click Add NAT Rule

Rule Type Source Destination Applied To
SNAT 192.168.0.0/16 172.16.0.29 UPLINK-TO-PYHSICAL
DNAT 172.16.0.30 192.168.10.9 (For testing only) UPLINK-TO-PYHSICAL
  • Create a load balancer, Networking > Load Balancing > Add
    • pcf-lb | small
    • Attach the load balancer to the T1 router INFRASTRUCTURE-T1
    • Create Server Pools and Virtual Servers
Virtual Server Name IP Port Server Pool Name Server Pool Monitoring
OpsManagerVirtualServer 172.16.0.30 22-8443 OpsManagerServerPool TCP port 443
RoutersVirtualServer 172.16.0.31 443 RouterServerPool TCP port 443
DiegoBrainsVirtualServer 172.16.0.32 2222 DiegoBrainServerPool TCP port 2222
- Attach the load balancer to the Virtual Servers
  • Create a New IP Pool for Orgs, those are created upon PAS deployment. Navigate to Networking > IPAM and click Add > pcf-ip-block - 192.168.32.0/19

  • Create a external SNAT IP Pool for the external networking. Go to Groups > IP Pools > Add

    • pcf-floating-ip-pool | 172.16.0.50 - 172.16.0.70 | 172.16.0.0/23 (CIDR)

NOTE: On the edgerouter X, define a static routing for 172.16.30.0/24 to route to 172.16.0.31 (NSX-T edge router IP). 172.16.30.0/24 is a transient network used to relay traffic from one edge router to another