Parses growatt solar inverter data and returns the data in a structured readable json object.
Tested with Growatt inverter GT0012F111 with WiFi module
npm install growatt-data-parser
var growattDataParser = require('growatt-data-parser');
var data = fs.readFileSync('test/testcapture-growatt-GT0012F111-01.cap');
var result = growattDataParser(data);
// simple server
var net = require('net');
var growattDataParser = require('growatt-data-parser');
net.createServer(function (socket) {
socket.on('data', function(data) {
const solardata = growattDataParser(data);
console.log(solardata);
});
}).listen('8000');
{
"wifimoduleserial":"AH55321111",
"inverterserial":"8F05491111",
"inverterstatus":1,
"ppv":745.3,
"vpv1":143.2,
"ipv1":2.5,
"ppv1":370.8,
"vpv2":141.9,
"ipv2":2.6,
"ppv2":374.5,
"pac":730.4,
"fac":50,
"vac1":229.1,
"iac1":3.1,
"pac1":731.9,
"vac2":0,
"iac2":0,
"pac2":0,
"vac3":0,
"iac3":0,
"pac3":0,
"etoday":11.7,
"etotal":307.1,
"htotal":435.04625,
"temperature":41.2,
"isofaultvalue":0,
"gfcifaultvalue":0,
"dcifaultvalue":0,
"vpvfaultvalue":0,
"vacfaultvalue":0,
"facfaultvalue":0,
"temperaturefaultvalue":0,
"faultcode":0,
"ipmtemp":43.4,
"pbusvolt":358.5,
"nbusvolt":0,
"checkstep":"0000",
"ipf":45,
"resetchk":"0059",
"deratingmode":"000000000000",
"epv1today":5.7,
"epv1total":149,
"epv2today":5.6,
"epv2total":149.7,
"epvtotal":298.7,
"rac":0,
"eractoday":0,
"eractotal":0,
"warningcode":"0000",
"warningvalue":"0000"
}