Virtual flow sensor was designed using the Wang-Mendel and the Takagi-Sugeno fuzzy structures.
For both method was used same set of data collected from the real sensor.
Example Charts from data validation:
Wang-Mendel validation results.
Takagi-Sugeno-Kang validation results.
About
Implementation of Wang-Mende and Takagi-Sugeno fuzzy structures in virtual flow sensor.