Merge pull request #1482 from RWTH-EBC/1481-wrong-sequence-descriptio…
Browse files Browse the repository at this point in the history
…n-for-internal-gains

correct the sequence in the description of internal gains output
  • Loading branch information
DaJansenGit committed Dec 20, 2023
2 parents 07a4c9b + f9d8ed8 commit e8aa7bd
Show file tree
Hide file tree
Showing 3 changed files with 11 additions and 10 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -172,17 +172,17 @@ model MultizonePostProcessing
each final quantity="Energy",
each final unit="J",
each displayUnit="kWh")
"Heat gains based on internal gains for each zone from persons, machines, and light"
"Heat gains based on internal gains for each zone from lights[1], machines[2], and persons[3]"
annotation (Placement(transformation(extent={{100,-122},{120,-102}}),
iconTransformation(extent={{100,-130},{120,-110}})));
Modelica.Blocks.Interfaces.RealInput QIntGains_flow[numZones,3](each final
quantity="HeatFlowRate", each final unit="W")
"Heat flow based on internal gains for each zone from persons, machines, and light"
"Heat flow based on internal gains for each zone from lights[1], machines[2], and persons[3]"
annotation (
Placement(transformation(extent={{-140,-140},{-100,-100}}),
iconTransformation(extent={{-140,-140},{-100,-100}})));
Modelica.Blocks.Continuous.Integrator QIntGainCalc[numZones,3]
"Heat gain based on internal gains for each zone from persons, machines, and light"
"Heat gain based on internal gains for each zone from lights[1], machines[2], and persons[3]"
annotation (Placement(transformation(extent={{58,-124},{74,-108}})));
equation
connect(TAirAverageCalc.u, TAir) annotation (Line(points={{56.4,96},{56.4,100},
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -155,7 +155,7 @@ partial model PartialMultizone "Partial model for multizone models"
//Swimming pool params
parameter Boolean use_pools_tot = false "use swimming pools within at least one zone of the multizone" annotation(Dialog(tab="Moisture", group="Pools"));
replaceable package MediumPoolWater = Media.Water annotation (choices(choice(redeclare
package Medium =
package Medium =
AixLib.Media.Water
"Water")), Dialog(enable=use_pools_tot,tab="Moisture", group="Pools"));

Expand Down Expand Up @@ -199,7 +199,7 @@ partial model PartialMultizone "Partial model for multizone models"
extent={{80,-100},{100,-80}})));
Modelica.Blocks.Interfaces.RealOutput QIntGains_flow[numZones,3](each final
quantity="HeatFlowRate", each final unit="W") if ASurTot > 0 or VAir > 0
"Heat flow based on internal gains for each zone from persons, machines, and light"
"Heat flow based on internal gains for each zone from lights[1], machines[2], and persons[3]"
annotation (Placement(transformation(extent={{100,-90},{
120,-70}}), iconTransformation(extent={{80,-100},{100,-80}})));
Modelica.Blocks.Interfaces.RealInput timeOpe
Expand Down
11 changes: 6 additions & 5 deletions AixLib/ThermalZones/ReducedOrder/ThermalZone/ThermalZone.mo
Original file line number Diff line number Diff line change
Expand Up @@ -4,7 +4,8 @@ model ThermalZone "Thermal zone containing moisture balance"
AixLib.ThermalZones.ReducedOrder.ThermalZone.BaseClasses.PartialThermalZone;

replaceable model corG = SolarGain.CorrectionGDoublePane
constrainedby AixLib.ThermalZones.ReducedOrder.SolarGain.BaseClasses.PartialCorrectionG
constrainedby
AixLib.ThermalZones.ReducedOrder.SolarGain.BaseClasses.PartialCorrectionG
"Model for correction of solar transmission"
annotation(choicesAllMatching=true);
parameter Integer internalGainsMode = 1
Expand Down Expand Up @@ -58,7 +59,8 @@ model ThermalZone "Thermal zone containing moisture balance"

// Pool parameters
replaceable package MediumPoolWater = AixLib.Media.Water
"Medium in the component" annotation (choices(choice(redeclare package Medium =
"Medium in the component" annotation (choices(choice(redeclare package
Medium =
AixLib.Media.Water
"Water")), Dialog(enable=use_pools,tab="Moisture", group="Pools"));
parameter Integer nPools(min=1)=1 "Number of pools in thermal zone" annotation(Dialog(enable=use_pools,tab="Moisture", group="Pools"));
Expand Down Expand Up @@ -334,7 +336,7 @@ model ThermalZone "Thermal zone containing moisture balance"
annotation (Placement(transformation(extent={{-84,61},{-68,77}})));
Modelica.Blocks.Interfaces.RealOutput QIntGains_flow[3](each final quantity="HeatFlowRate",
each final unit="W") if ATot > 0
"Heat flow based on internal gains from persons, machines, and light"
"Heat flow based on internal gains from lights[1], machines[2], and persons[3]"
annotation (
Placement(transformation(extent={{100,-50},{120,-30}}),
iconTransformation(extent={{100,-50},{120,-30}})));
Expand Down Expand Up @@ -776,8 +778,7 @@ elseif use_MechanicalAirExchange and not use_NaturalAirExchange then
{-21.2,-10}},
color={0,0,127},
pattern=LinePattern.Dash));
else
connect(addInfVen.y, cO2Balance.airExc) annotation (Line(points={{-29.5,-27},
else connect(addInfVen.y, cO2Balance.airExc) annotation (Line(points={{-29.5,-27},
{-24,-27},{-24,-34},{12,-34},{12,-63.6},{16,-63.6}},
color={0,0,127}));
connect(addInfVen.y, airExc.ventRate) annotation (Line(points={{-29.5,-27},
Expand Down