Skip to content

jrbenito/PIMA-node

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

6 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

PIMA-node

Reads PIMA protocol from compatible energy meters (serial) and restransmits data in a Computourist style

PIMA Protocol Library

A library to read data from energy meters compliant with Brazilian standards.

Intruction

PIMA stands for Protocolo para Infraestrutura de Medição Avançada (Protocol for Advanced Measurement Infrastructure, free translation) and is defined as Brazilian standard for smart eneregy metering products comercialized in Brazil.

This library is designed for interpret PIMA packets read from unidirectional assynchronous serial available on digital energy meters available in Brazil.

Acknowloges

This started as a weekend project to monitor energy consumption and generation at home. I had access to a energy meter manufactured by brazilian company Nansen, model Vector PAR. This model is equiped with a assynchronous unidirectional serial port that constantly outputs PIMA packets. Hence, this works with Vector meter but shall work with any other meter compliant with PIMA standards.

Library only interprets packages and keep a register of last read values. Interfacing and reading of serial data is left out to the application code in the same fashion as Mikal Hart TinyGPS Library.

Until now, only implemented energy quantities available on the Vector PAR output, other quantities shall be easy to add but I have no means to test. I will gladly merge PRs that include new quantities. Again, Vector is unidirectional, so library only interpret received packets.

PIMA Packets

A PIMA packet is composed as below:

2 Bytes 5 Bytes 1 Byte 2 Bytes N Bytes 2 Bytes
Preamble Identifier Size Escope + Index Data CRC16
  • Preamble marks the start of packet and is composed by 2 hex bytes 0xAA 0x55
  • Identifier is the serial number and is formatted as 5 bytes BCD (representing a 10 digit number)
  • Size is the sum of bytes in Escope, Index and DATA (2 + N bytes)
  • Data is the value for quantitie represented by Index
  • CRC16 is the ANSI-CRC16 calculated over all bytes except Preamble and CRC itself

Only on Escope and Index are allowed per packet.

Escopes and Indexes

Until now, the following quantities are known to the library:

  • Active Energy direct (KWh) - Escope 0x0A Index 0x02
  • Inductive Reactive Energy direct (KVArh) - Escope 0x0A Index 0x07
  • Capacitive Reactive Energy direct (KVArh) - Escope 0x0A Index 0x0C
  • Active Energy reverse (KWh) - Escope 0x0A Index 0x51

While Vector PAR provide visual indication for capactive and inductive energy in reverse direction it does not transmit it over PIMA serial interface. It shall be simple to add support to these quantities in the future versions of this library.

References

Disclamair

This is not meant to be a reference for the PIMA protocol and it is not guarantee to work on all equipment (only tested on Vector PAR). If you are pursuing a reference, please refers to the ABNT/INMETRO/ANEEL applicable standards and legislation.

Energy meters are generally connect to mains BEFORE any breaker protection DO NOT try to connect anything to it if you are not qualified for this kind of work. I repeat: DO NOT TRY TO CONNECT/INTERFACE WITH A ENERGY METER TIED TO MAINS.

Also, be aware that in many countries (Brazil included), energy meter is placed in a cabinet sealed by energy company and break the seal is considered crime. YOU MAY BE charged for stealing energy. My Vector PAR was not provided by energy company but installed inside my home just after the company meter so, I did not messed with company´s sealed cabinet.

AUTHOR NOR ANY OTHER CONTRIBUTOR ARE RESPONSIBLE for any consequences of its use, including accidents of any kind caused, but not limited, by misconnection, lack of knowledge in electricity or electronics, etc. BE ADVISED: energy kills! Steal energy is crime! Mess with company´s meter without proper authorization can be considered crime and fines are applicable.