What's Changed

Breaking Changes

Moving, renaming, or deleting elements or enumerations.

  • Fix WaterHeaterImprovement/PipeInsulated element by @shorowit in #401
  • Various additional value constraints by @shorowit in #402
  • Updating HPXML namespace and versions to v4.0 by @shorowit in #392

Non-breaking Changes

Adding elements or enumerations.

Full Changelog: v4.0-rc3...v4.0-rc4

HPXML v4.0 - Release Candidate 3

19 Jan 16:36
Compare
Choose a tag to compare
Pre-release

What's Changed

Breaking Changes

Moving, renaming, or deleting elements or enumerations.

Non-breaking Changes

Adding elements or enumerations.

Full Changelog: v4.0-rc2...v4.0-rc3

HPXML v4.0 - Release Candidate 2

17 Oct 19:07
Compare
Choose a tag to compare
Pre-release

A few minor fixes we found since v4.0-rc1:

What's Changed

Breaking Changes

Non-breaking Changes

Full Changelog: v4.0-rc1...v4.0-rc2

HPXML v4.0 - Release Candidate 1

26 Sep 21:37
Compare
Choose a tag to compare
Pre-release

Changelog

Breaking Changes

Moving, renaming, or deleting elements or enumerations.

Non-breaking Changes

Adding elements or enumerations.

Maintenance Changes

Changes that shouldn't affect anything.

New Contributors

Full Changelog: v3.1...v4.0

HPXML 3.1

29 Jun 21:23
f7d49e5
Compare
Choose a tag to compare

v3.1 Changelog

New Contributors

Full Changelog: v3.0...v3.1

HPXML 3.0

01 Nov 21:34
d62da65
Compare
Choose a tag to compare

v3.0 Changelog

  • [breaking change] Green Building Verification from RESO #66
  • [breaking change] Multiple IECC climate zones #123
  • [breaking change] Addresses inconsistencies #124
  • HeatingSystem/ElectricAuxiliaryEnergy #140
  • Additional WaterFixture fields #142
  • Clothes Washer IMEF/IWF #144
  • [breaking change] Clothes Dryer CEF (and EF bugfix) #145
  • Additional PV fields #147
  • Additional heat pump types #148
  • Add rim joists perimeter field #150
  • Adds extension element for CeilingFan #151
  • Add Quantity field for CeilingFan/WaterFixture #152
  • Clarifies UnderSlabInsulationWidth description #153
  • Adds VentilationFan/AttachedToHVACDistributionSystem #154
  • Add Azimuth/Orientation to RimJoists and FoundationWalls #155
  • [breaking change] Standardize Locations #156
  • Adds generic "coal" fuel type #157
  • Fix typo in AttachedToWaterHeatingSystem description #158
  • Adds fuel type element for heat pumps #159
  • Adds PV element for number of panels #160
  • Adds LeakinessDescription element to doors/windows/skylights #161
  • Additional heating system properties #162
  • Presence of Insulation #163
  • Adds InfiltrationVolume element #164
  • [breaking change] Lighting fraction improvements #165
  • [breaking change] Deprecates items #167
  • Adds WaterHeaterInsulation fields #171
  • Adds Refrigerator Type choice #173
  • Adds "other" enumeration for Occupancy #175
  • [breaking change] Reworking HPXML's Enclosure #181
  • Update HPXML version to 3.0 #182
  • [breaking change] Adds desuperheater flexibility #184
  • Adds SolarThermalSystem performance elements #185
  • Adds ASRE/ATRE for mechanical ventilation #186
  • New DuctLocation choices #187
  • [breaking change] Allow insulation location to be layer-specific #188
  • [breaking change] Window/Skylight Interior Shading Fraction #189
  • EV Chargers #190
  • Adding customer comments element #191
  • Adding house batteries #192
  • Adding pipe diameter and some other elements to hydronic systems #193
  • Adding dataSource attribute #194
  • Door area documentation #196
  • [breaking change] Fixing project ids #197
  • Home Automation #198
  • DHW Controllers #200
  • [breaking change] Window sub-components #202
  • Additional AdjacentTo enumerations #203
  • Percent duct leakage #206
  • [breaking change] Clarify PV inverter efficiency value #207
  • updating BPI-2101 enums in GreenBuildingVerification/Type #210

HPXML 2.3

03 Aug 17:52
Compare
Choose a tag to compare

HPXML 2.3 is a backwards compatible release that adds several new features to the standard. The deadline for adoption of this version is November 1, 2018. This will ensure that senders and receivers of data will be coordinated in their upgrade efforts.

Changelog

  • Clarifying documentation for BPI2400Inputs/CalibrationQualification #138
  • Adding the FloorFurnace heating system type #137
  • Adding optional reference to a HeatingSystem from a HeatPump to indicate that it provides backup heat #136
  • Adding ModeledUsage/ElectricityDemandKW #135
  • Adding ExternalResource element #134
  • Adding 2x3 stud size enumeration #133
  • Adding 'medium dark' to WallAndRoofColor #131
  • Adding solar absorptance and emittance for non-foundation walls and roofs #129
  • Adding WMO Station Number #122
  • Adding Slab/Thickness #121
  • Adding UniformEnergyFactor for water heaters #120
  • Additional vent fan types #114
  • Adding drain water heat recovery extension element #112
  • Clarify hot water distribution fields #109
  • Adding appliance fields #108
  • Adding FuelTypesAvailable #106

HPXML 2.2.1

14 Sep 20:59
Compare
Choose a tag to compare

HPXML 2.2.1 is a backwards compatible patch release to 2.2 to provide the following change:

Changelog

  • Added the "preconstruction" event type to support Home Energy Score #104.

HPXML 2.2

03 Aug 21:08
Compare
Choose a tag to compare

HPXML 2.2 is a (mostly) backwards compatible release.

Changelog

  • Add RadiantBarrierLocation enumeration: underside of rafters #16
  • Allow zero for NumberOfBedrooms #24
  • Add EventType enumeration: supervised audit #26 [note: this was never implemented. We decided against it.]
  • Allow multiple WaterHeatingSystem/ThirdPartyCertification elements #27
  • Document window areas as the total surface area for a group of windows #30
  • Add HotWaterDistribution element #31
  • Add HVACThirdPartCertification enumeration: Energy Star Most Efficient #32
  • Add AirDistributionInfo/TotalExternalStaticPressureMeasurement elements #33
  • Add example files from HPXML Toolbox #35
  • Add BuildingSummary/SiteVerticalSurroundings element #64
  • Add PlugLoadType enumeration: sauna #41
  • Add PlugLoadType enumeration: well pump #42
  • Add VentilationFan/TheirPartyCertification element #78
  • Add HVACDistributionImprovement/DuctSystemSealedYearMonth element #45
  • Add HVACMaintenance/TuneAndRepairYearMonth element #48
  • Add HVACMaintenance/AirFilter element #67
  • Add WaterHeatingSystem/HasGeothermalDesuperheater element #51
  • Add Systems/Wind element #71
  • Add YearInstalled, AnnualOutput, and LevelizedCostOfEnergy to PV and Wind #53
  • Add PVSystemOwnership enumerations: power purchase agreement, utility owned, other #54
  • Add HVACThirdPartyCertification enumeration: NEEP Cold-Climate Air-Source Heat Pump Specification #56
  • Add PlugLoad/Location element #72
  • Remove trailing space from WaterType enumeration "indoor water", leave original #92
  • Add EnergyScore/OtherScoreType and EnergyScore/ScoreDate elements #65
  • Enforce AirInfiltrationMeasurement/HousePressure to be positive #37 (breaking change)

HPXML 2.1

05 Jan 16:39
Compare
Choose a tag to compare

HPXML 2.1 is a minor backwards compatible release.

Bugfixes

  • Allowing a non-integer and zero number of residents #10
  • Added extension sub-element to ambient and rubble stone foundation types #2

Non-breaking changes

  • Added weather station used in model simulation or utility bill regression analysis (trac #307)
  • Added flag to indicate whether duct leakage was total or to outside (trac #308)
  • Updated BPI 2400 elements to include simplified bias errors by end use
  • Added water fixture element #6
  • Added first hour rating, gallons per minute to water heaters #8
  • Added emissions rate to wood stove #8
  • Added "direct expansion" enumeration to geothermal loop #8
  • Added pipe R-value under HVAC distribution #8
  • Added lighting fixture #6
  • Added moveable insulation R-value to windows #6
  • Added Temperature-initiated shower flow restriction valve #15
  • Added HoursPerDay under PoolPump/PumpSpeed and deprecated it under PoolPump #11