2 changes: 1 addition & 1 deletion Documentation/property-facet.md
Original file line number Diff line number Diff line change
Expand Up @@ -79,7 +79,7 @@ The **Property Facet** is considered to be one of the most commonly used facets
| **Base Name** | ✔️ | ✔️ | Any text property name. Standardised buildingSMART property names can be found in the buildingSMART documentation. | The property must exist in the specified property set and have a non-empty value. |
| **Data Type** | ❌ | ✔️ | A valid data type compatible with the referenced schema version, expressed in UPPERCASE. | The value must use the specified data type. The units specified in the IDS use the [IDS units table](units.md), though the project may use any unit, so project values will have to be converted to the SI unit before comparison. User Interfaces are permitted to display any unit that the developers or the users prefer. |
| **Value** | ❌ | ✔️ | Any value appropriate to the data type of the property. If not specified, any non-empty value is allowed. The value of measures types will be stored according to the unit defined in the [IDS units table](units.md) | The value of the attribute must match. To specify numbers, you must use a dot as the decimal separator, and not use a thousands separator (e.g. `4.2` is valid, but `1.234,5` is invalid). Scientific notation is allowed (e.g. `1e3` to represent `1000`). To specify true or false, you must specify `TRUE` or `FALSE` as uppercase characters. |
| **URI** | ❌ | ❌ | A URI identifying the property compliant with ISO 23386 | You may find valid URIs using the [buildingSMART Data Dictionary](https://search.bsdd.buildingsmart.org/), for example for a [Fire Rating](https://search.bsdd.buildingsmart.org/Property/Index/115666) property. |
| **URI** | ❌ | ❌ | A URI identifying the property compliant with ISO 23386 | You may find valid URIs using the [buildingSMART Data Dictionary](https://search.bsdd.buildingsmart.org/), for example for a [Fire Rating](https://identifier.buildingsmart.org/uri/buildingsmart/ifc/4.3/prop/FireRating) property. |

## Examples