Skip to content

Releases: amunters/bitx40-raduino-v2

small bugfix

12 Feb 01:00
b231df1
Compare
Choose a tag to compare
  • renamed "CLARIFIER" to "Passband Tuning (PBT)" as this seems a more appropriate name for this function
  • improved the code so that the si5351 does not keep receiving tuning updates once the frequency has reached the upper or lower limit

Added BFO calibration parameters for CWL and CWU

14 Jan 00:24
39297d9
Compare
Choose a tag to compare

v2.03

  • Added BFO calibration parameters for CWL and CWU to optimize the performance in CW mode
  • Revised and improved the calibration procedures (tks Michael, VE3WMB)
  • Corrected a bug that in certain scenarios mode switching did not function correctly
  • Updated the instructions for the CW-CARRIER mod: Advise to use a 4.7K resistor instead of 10K in order to ensure full output power in CW mode
  • Added capability (see line 31) to display the user's callsign on the second line of the LCD
  • Added capability (see line 32) to adjust the delay time for 'fast tuning' (when the tuning pot is at either end of the range)

bug correction

19 Dec 23:29
54793b1
Compare
Choose a tag to compare
  • Fixed another bug in the calibration procedure
  • Slightly changed the initial BFO frequencies to 11998800 Hz (LSB) and 11996600 Hz (USB)

bug correction

18 Dec 23:51
e8e443c
Compare
Choose a tag to compare

Fixed a bug that the VFO setting (high/low side of IF) didn't return to the original state after executing the calibration procedure

initial release of v2

16 Dec 17:37
ca604e6
Compare
Choose a tag to compare
v2.00

Update operating-instructions.md