removed rxns comments that started with the word fit #626
+0
−23
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
I got the following trace when simulating an RMG-genrated Chemkin file usng RMG's constant T/P reactor:
RMG did not read the flux pair correctly from C6H5_C4H4_Mebel kinetic library, and read the following line which was taken from the library comment.
This is the reaction it errored on:
For a quick solution while using
rmg.chemkin.load_chemkin_file
, I removed all the comments inside the reactions comments that started with the word 'fit' inside theC6H5_C4H4_Mebel
library.