Skip to content

Steps to use MATLAB calibration toolbox for lidar camera calibration

Notifications You must be signed in to change notification settings

NingMingHao/LidarCameraCalibration

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

4 Commits
 
 
 
 
 
 
 
 

Repository files navigation

LidarCameraCalibration

Steps to use MATLAB calibration toolbox for lidar camera calibration

This repo includes the steps to use the MATLAB single camera calibration toolbox and lidar camera calibration toolbox.

It covers the following topics:

Data Collection

The checkerboard used in this repo is a 9x6 checkerboard with 90mm square size, the padding is 60mm, as shown in the following figure.

Checkerboard

The data is collected as rosbag files, the lidars and cameras are fixed on a parked vehicle, the checkerboard is hold by a person (it's recommended to use a tripod to hold the checkerboard).

Notes for data collection:

  • The background should be clear, try to avoid objects with similar pattern as the checkerboard, like walls, fences, etc.
  • If holding the checkerboard by hand, please try to keep the checkerboard far from human body, so that the checkboard plane can be clearly detected by the lidar, otherwise the points from human body may also be clustered into the checkerboard plane, which will affect the calibration result.
  • Don't block the plane by the human hand.
  • The checkerboard should be placed in the field of view of the camera and lidar, and the checkerboard should be visible by both camera and lidar.
  • For the camera only calibration, the checkerboard can be placed in any orientation.
  • For the lidar camera calibration, the checkerboard should not be placed in parallel with the lidar scanning plane, otherwise the four corners of the checkerboard may not be estimated correctly. A recommended orientation is shown in the following figure.

RecommendedCheckerboardOrientation

Data Preprocessing

Use this parseRosbag.m to convert the rosbag file to png and pcd files. This will synchronize the lidar point cloud and camera image, and downsample the point cloud and image to the specified rate. This script is based on this link. Here you need to modify the following parameters:

  • rosbag_path: the rosbag file path
  • save_path: the directory to save the files
  • imageTopic: the image topic name
  • lidarTopic: the lidar topic name
  • downsample_rate: the downsample rate for the lidar point cloud and image, typically the lidar runs at 10Hz, it's not necessary to save all the point clouds and images, so we can downsample the point cloud and image to 1Hz or 0.5Hz.

Single Camera Calibration

Camera Calibration

  • Launch the single camera calibration app
  • Load the images from files, use Checkerboard as the pattern, and 90mm as the square size, choose Image distortion as High
  • In Options, choose 2 Coefficients for Radial distortion, and Tangential distortion as Enabled, this is the commonly used plumb bob model
  • Remove the unwanted images in Data Browser, and then Calibrate
  • After the calibration, you can check the reprojection error, and then export the calibration result
  • It's recommended to save the calibration session, so that you can load it later and check the reprojection error again

Undistort Images

Use the undist_all_images.m script to undistort the images, it also generate a new undistCameraParams to store the parameters for the undistorted images, which will be used in the lidar camera calibration. Here you need to modify the following parameters:

  • 'save_path': the parent folder where you save the paired images and point clouds

You can also run the convert_intrinsic_into_yaml.m to convert the intrinsic parameters into yaml file, which can be used in the image_proc ROS package.

Lidar Camera Calibration

Preparation

Before you start the lidar camera calibration, you are recommended to check the following things:

  • Check the UndistImages folder, delete the images that are not good, like the images with the checkerboard not fully visible. Even though the calibration toolbox can tell the bad images, it's better to remove them manually.
  • Run the crop_points.m to crop the point clouds, it limits the point cloud into a region of interest, where you may remove the ground plane, or the points that are too far away from the camera, etc. This will reduce the computation time for the calibration. This script will only look for the point clouds with corresponding undistorted images, so you can safely delete unwanted images in the UndistImages folder.

Lidar Camera Calibration

  • Launch the lidar camera calibration app
  • Load the undistorted images and point clouds, choose Checkerboard as the pattern, and 90mm as the square size, also specify the padding size as 60mm
  • Use Fixed Intrinsic for the camera, and load the undistCameraParams.mat file
  • You may not need the Remove Ground option, if you have already cropped the point clouds using the crop_points.m script
  • Try to Detect Checkerboard first, if it fails, you can try to adjust the Cluster Threshold and Dimension Tolerance to make it work
    • Cluster Threshold — Clustering threshold for two adjacent points in the point cloud, specified in meters. The clustering process is based on the Euclidean distance between adjacent points. If the distance between two adjacent points is less than the clustering threshold, both points belong to the same cluster. Low-resolution lidar sensors require a higher Cluster Threshold, while high-resolution lidar sensors benefit from a lower Cluster Threshold.
    • Dimension Tolerance — Tolerance for uncertainty in the rectangular plane dimensions, specified in the range [0,1]. A higher Dimension Tolerance indicates a more tolerant range for the rectangular plane dimensions.
  • If the matched data is not enough, you can then try to Select Checkerboard manually, where you can select the checkerboard plane points manually. If you didn't crop the points, you may struggle to tune the view angle to select the checkerboard plane points, so it's recommended to crop the points first.
  • Then Calibrate, after the calibration, you can check the reprojection error, and then export the calibration result.
  • When you find the reprojection error is quite high even if the checkerboard plane is clearly visible, you may need to adjust the Initial Transform to make the checkerboard plane more parallel with the lidar scanning plane. For Initial Transform, this is necessary when the orientation of the two sensors are not aligned, you need to use the rigid3d function to define a rigid3d class for initial transform. Please note the T used in Matlab is not the common way as we use:

Rigid3d

  • It's also recommended to save the calibration session, so that you can load it later and check the reprojection error again.

Export the calibration result into ROS desired format

Through the Lidar Camera Calibration, we can get the transformation matrix that transforms the lidar points into the camera frame.

However, the transformation matrix is not in the format that can be used in ROS. So we need to convert the transformation matrix into the format that can be used in ROS. Here we use the convert_tform_to_ROS.m script to convert the transformation matrix into yaml file, where you can use it in the static transform publisher to publish the transformation between the lidar and camera frame.

The desired format is shown below: static_transform_publisher x y z yaw pitch roll frame_id child_frame_id period_in_ms (yaw is rotation about Z, pitch is rotation about Y, and roll is rotation about X) in radians. The frame_id is typically the lidar frame, and the child_frame_id is typically the camera frame. So the translation vector is the position of the camera frame in the lidar frame, and the rotation vector is the rotation of the camera frame in the lidar frame.