OpenStudio-HPXML version 1.4.0 has been released. The OpenStudio-HPXML workflow uses HPXML building description files to run residential simulations on the Department of Energy's OpenStudio/EnergyPlus building simulation platform.

Two packages are available, a minimal zip with a handful of weather files and a full zip with all US TMY3 weather files. OpenStudio-HPXML v1.4.0 uses OpenStudio v3.4.0, EnergyPlus v22.1.0, and a proposed HPXML v4.0. Please visit the OpenStudio-HPXML v1.4.0 documentation for instructions on how to get started, how to generate an appropriate HPXML file, etc.

New Features

  • Updates to OpenStudio 3.4.0/EnergyPlus 22.1.
  • High-level optional OccupancyCalculationType input to specify operational vs asset calculation. Defaults to asset. If operational, NumberofResidents is required.
  • Allows calculating one or more emissions scenarios (e.g., high renewable penetration vs business as usual) for different emissions types (e.g., CO2e).
  • New ReportUtilityBills reporting measure: adds a new results_bills.csv output file to summarize calculated utility bills.
  • Switches from EnergyPlus SQL output to MessagePack output for faster performance and reduced file sizes when requesting timeseries outputs.
  • New heat pump capabilities:
    • Breaking change: Replaces the UseMaxLoadForHeatPumps sizing option with HeatPumpSizingMethodology, which has three choices:
      • ACCA: nominal capacity sized per ACCA Manual J/S based on cooling design loads, with some oversizing allowances for larger heating design loads.
      • HERS (default): nominal capacity sized equal to the larger of heating/cooling design loads.
      • MaxLoad: nominal capacity sized based on the larger of heating/cooling design loads, while taking into account the heat pump's capacity retention at the design temperature.
    • Allows the separate backup system to be a central system (e.g., central furnace w/ ducts). Previously only non-central system types were allowed.
    • Heat pumps with switchover temperatures are now autosized by taking into account the switchover temperature, if higher than the heating design temperature.
    • Allows BackupHeatingLockoutTemperature as an optional input to control integrated backup heating availability during, e.g., a thermostat heating setback recovery event; defaults to 40F.
  • New water heating capabilities:
    • Allows conventional storage tank water heaters to use a stratified (rather than mixed) tank model via extension/TankModelType; higher precision but runtime penalty. Defaults to mixed.
    • Allows operating mode (standard vs heat pump only) for heat pump water heaters (HPWHs) via extension/OperatingMode. Defaults to standard.
    • Updates combi boiler model to be simpler, faster, and more robust by using separate space/water heating plant loops and boilers.
  • New capabilities for hourly/sub-hourly scheduling via schedule CSV files:
    • Detailed HVAC and water heater setpoints.
    • Detailed heat pump water heater operating modes.
  • EnergyPlus modeling changes:
    • Switches from ScriptF to CarrollMRT radiant exchange algorithm.
    • Updates HVAC fans to use fan power law (cubic relationship between fan speed and power).
    • Updates HVAC rated fan power assumption per ASHRAE 1449-RP.
  • Allows specifying a StormWindow element for windows/skylights; U-factors and SHGCs are automatically adjusted.
  • Allows an optional AirInfiltrationMeasurement/InfiltrationHeight input.
  • Allows an optional Battery/UsableCapacity input; now defaults to 0.9 x NominalCapacity (previously 0.8).
  • For CFIS systems, allows an optional extension/VentilationOnlyModeAirflowFraction input to address duct losses during ventilation only mode.
  • Breaking change: Each VentilationFan must have one (and only one) UsedFor... element set to true.
  • BuildResidentialHPXML measure:
    • Breaking change: Changes the zip code argument name to site_zip_code.
    • Adds optional arguments for schedule CSV files, HPWH operating mode, water heater tank model, storm windows, heat pump lockout temperature, battery usable capacity, and emissions scenarios.
    • Adds support for ambient foundations for single-family attached and apartment units.
    • Adds support for unconditioned attics for apartment units.
    • Adds an optional argument to store additional custom properties in the HPXML file.
    • Adds an optional argument for whether the HPXML file is written with default values applied; defaults to false.
    • Adds an optional argument for whether the HPXML file is validated; defaults to false.
  • ReportSimulationOutput measure:
    • Breaking change: New "End Use: <Fuel>: Heating Heat Pump Backup" output, disaggregated from "End Use: <Fuel>: Heating".
    • Adds "Energy Use: Total" and "Energy Use: Net" columns to the annual results output file; allows timeseries outputs.
    • Adds a "Fuel Use: Electricity: Net" timeseries output column for homes with electricity generation.
    • Adds optional argument for requesting timeseries EnergyPlus output variables.
    • Adds ability to include TimeDST and/or TimeUTC timestamp column(s) in results_timeseries.csv.
    • Timestamps in results_timeseries.csv are output in ISO 8601 standard format.
    • Allows user-specified annual/timeseries output file names.
  • ReportHPXMLOutput measure:
    • Adds "Enclosure: Floor Area Foundation" output row in results_hpxml.csv.
  • Adds support for shared hot water recirculation systems controlled by temperature.
  • Relaxes requirement for ConditionedFloorAreaServed for air distribution systems; now only needed if duct surface areas not provided.
  • Allows MessagePack annual/timeseries output files to be generated instead of CSV/JSON.

Bugfixes

  • Adds more stringent limits for AirflowDefectRatio and ChargeDefectRatio (now allows values from 1/10th to 10x the design value).
  • Catches case where leap year is specified but weather file does not contain 8784 hours.
  • Fixes possible HVAC sizing error if design temperature difference (TD) is negative.
  • Fixes an error if there is a pool or hot tub, but the pump Type is set to "none".
  • Adds more decimal places in output files as needed for simulations with shorter timesteps and/or abbreviated run periods.
  • Timeseries output fixes: some outputs off by 1 hour; possible negative combi boiler values.
  • Fixes range hood ventilation interaction with infiltration to take into account the location of the cooking range.
  • Fixes possible EMS error for ventilation systems with low (but non-zero) flow rates.
  • Fixes documentation for Overhangs/Depth inputs; units should be ft and not inches.
  • The WaterFixturesUsageMultiplier input now also applies to general water use internal gains and recirculation pump energy (for some control types).
  • BuildResidentialHPXML measure:
    • Fixes units for "Cooling System: Cooling Capacity" argument (Btu/hr, not tons).
    • Fixes incorrect outside boundary condition for shared gable walls of cathedral ceilings, now set to adiabatic.