Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

humidity went negative #2

Open
ScottPesetsky opened this issue Sep 3, 2014 · 0 comments
Open

humidity went negative #2

ScottPesetsky opened this issue Sep 3, 2014 · 0 comments

Comments

@ScottPesetsky
Copy link

Climate module was attached by cord. Breathed on climate module then held away. Tessel reported negative reading. Awesome device!

Degrees: 82.3043F Humidity: 110.0316%RH
Degrees: 82.5360F Humidity: 111.1913%RH
Degrees: 82.7676F Humidity: 112.3357%RH
Degrees: 82.9607F Humidity: 113.3886%RH
Degrees: 83.0958F Humidity: 114.3575%RH
Degrees: 83.2309F Humidity: 115.1357%RH
Degrees: 83.3275F Humidity: 116.0512%RH
Degrees: 82.9221F Humidity: 116.6540%RH
Degrees: 82.3043F Humidity: 117.2338%RH
Degrees: 81.9375F Humidity: 117.7984%RH
Degrees: 81.7058F Humidity: 118.3629%RH
Degrees: 81.3970F Humidity: 118.8894%RH
Degrees: 81.2039F Humidity: 118.7368%RH
Degrees: 80.9722F Humidity: -5.7368%RH
Degrees: 80.8178F Humidity: -5.2790%RH
Degrees: 80.7213F Humidity: -4.8136%RH
Degrees: 80.6441F Humidity: -4.3711%RH
Degrees: 80.5668F Humidity: -3.9591%RH
Degrees: 80.4317F Humidity: -3.6006%RH
Degrees: 80.2773F Humidity: -3.2267%RH
Degrees: 80.2193F Humidity: -2.9063%RH
Degrees: 80.1614F Humidity: -2.5858%RH

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

1 participant