Rising edge trigger doesn't work properly #11

Open
tgtakaoka opened this issue Feb 19, 2023 · 2 comments
Open

Rising edge trigger doesn't work properly #11

tgtakaoka opened this issue Feb 19, 2023 · 2 comments

Comments

@tgtakaoka
Copy link

tgtakaoka commented Feb 19, 2023

Logic version: 2.4.6

The rising edge trigger of Simple Parallel anayzer doesn't work as expected (see screenshot).

It samples data (AD0~7) at falling edge of trigger signal (#RD and #WR), and the UI shows rising arrow mark on falling edge.

image

@tgtakaoka tgtakaoka changed the title Raising edge trigger doesn't work properly Rising edge trigger doesn't work properly Feb 19, 2023
@tgtakaoka
Copy link
Author

Probably fixed by dc343bc, waiting for the fix is published via Logic update.

@timreyes
Copy link

Yes, sorry for the bug! We plan on implementing the fix in the next release of the Logic 2 software (2.4.7).