BL602 doesn't saves and restores state. Setting Flag 12 to restore LED state crashing it. #1128

Open
visilya opened this issue Mar 14, 2024 · 0 comments
Labels
bug Something isn't working

Comments

@visilya
Copy link

visilya commented Mar 14, 2024

When setting "Flag 12" ([LED] Remember LED driver state (RGBCW, enable, brightness, temperature) after reboot) it rises error.

Current task sp data:
RA:30303030, mstatus:80007880
A0:420295e8 A1:00000000 A2:00000000 A3:00000000 A4:00000000 A5:00000000 A6:00000000 A7:00000000
T0:98000000 T1:000007ff T2:00000000 T3:00000000 T4:00000000 T5:00000000 T6:33333200
S0:30303030 S1:30303030 S2:30303030 S3:30303030 S4:30303030 S5:30303030 S6:30303030 S7:30303030
S8:30303030 S9:30303030 S10:30303030 S11:30303030
Exception Entry--->>>
mcause 38000002, mepc 30303030, mtval 00000000
Exception code: 2
  msg: Illegal instruction

Probably this is about not emplemented ReadLED and SaveLED code

@openshwprojects openshwprojects added the bug Something isn't working label Mar 14, 2024