New FFT code is not correct with some floating point Modular on HPAC #243

Open
cyrilbouvier opened this issue Dec 19, 2019 · 0 comments
Open
Assignees

Comments

@cyrilbouvier
Copy link
Member

Tests Modular<float, double> and ModularExtended failed on HPAC with n >= 2^4 (hint: last steps and first steps may be buggy)