Measurement finished right after core.run() call #48

Open
TKosir opened this issue Jul 11, 2023 · 0 comments
Open

Measurement finished right after core.run() call #48

TKosir opened this issue Jul 11, 2023 · 0 comments
Labels
bug Something isn't working

Comments

@TKosir
Copy link
Collaborator

TKosir commented Jul 11, 2023

Some users report that calling core.run() method immediately stops the acquisition although the measurement is set up correctly. The second run() call either then results in successful measurement or in a "cannot keep up with acquisition hardware" error in some cases when NI cards are used.