Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Transmission tables with attenuator #1

Open
grazwegian opened this issue Oct 21, 2021 · 0 comments
Open

Transmission tables with attenuator #1

grazwegian opened this issue Oct 21, 2021 · 0 comments

Comments

@grazwegian
Copy link
Collaborator

What do you think would be the best way to handle the transmission when the attenuator is in? Currently we have a per detector file stix_transmission_highres_20210303.csv which does not include attenuation and a component file which includes the transmission through the attenuator stix_transmission_by_component_highres_20210303.csv. The information here can be combined during processing when the attenuator is in but this might not be the cleanest way to handle it.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

1 participant