nguyensinhton opened this issue Aug 3, 2023 · 0 comments
Labels
bug Something isn't working

Comments

@nguyensinhton
Copy link

nguyensinhton commented Aug 3, 2023

Background Work

FireSim Version and Hash

1.17.1

OS Setup

ubuntu 20.04.06 LTS

Other Setup

VCU118 board rev 1.1

Current Behavior

Hi everyone,
I am following the guide, in the step "firesim runworkload" (https://docs.fires.im/en/latest/Getting-Started-Guides/On-Premises-FPGA-Getting-Started/Running-Simulations/Running-Single-Node-Simulation-Xilinx-VCU118.html).

I am facing a problem related to "Linux booting."
When I executed the command "screen -r fsim0" to directly attach to the console of the simulated system,
However, the system froze, and I received the following message:

Script started, file is uartlog
Using: 0000:01:00.0, BAR ID: 0, PCI Vendor ID: 0x10ee, PCI Device ID: 0x903f
Opening /sys/bus/pci/devices/0000:01:00.0/vendor
Opening /sys/bus/pci/devices/0000:01:00.0/device
examining xdma/.
examining xdma/..
examining xdma/xdma0_h2c_0
Using xdma write queue: /dev/xdma0_h2c_0
Using xdma read queue: /dev/xdma0_c2h_0
command line for program 0. argc=29:
+permissive +macaddr0=00:12:6D:00:00:02 +blkdev0=linux-uniform0-br-base.img +niclog0=niclog0 +blkdev-log0=blkdev-log0 +trace-select=1 +trace-start=0 +trace-end=-1 +trace-output-format=0 +dwarf-file-name=linux-uniform0-br-base-bin-dwarf +autocounter-readrate=0 +autocounter-filename-base=AUTOCOUNTERFILE +drj_dtb=linux-uniform0-br-base-bin.dtb +drj_bin=linux-uniform0-br-base-bin +drj_rom=linux-uniform0-br-base-bin.rom +print-start=0 +print-end=-1 +linklatency0=6405 +netbw0=200 +shmemportname0=default +domain=0x0000 +bus=0x01 +device=0x00 +function=0x0 +bar=0x0 +pci-vendor=0x10ee +pci-device=0x903f +permissive-off linux-uniform0-br-base-bin
UART0 is here (stdin/stdout).
TraceRV 0: Tracing disabled, since +tracefile was not provided.

The boot process freezes at this point, and I'm unable to see linux booting.
I checked dmesg and got a ERROR as below :

[T4 Thg 8 2 14:05:13 2023] i915 0000:00:02.0: [drm] ERROR Atomic update failure on pipe A (start=470390 end=470391) time 6197 us, min 1073, max 1079, scanline start 834, end 39
[T4 Thg 8 2 14:05:14 2023] i915 0000:00:02.0: [drm] ERROR Atomic update failure on pipe A (start=470423 end=470424) time 5546 us, min 1073, max 1079, scanline start 931, end 145
[T4 Thg 8 2 14:05:14 2023] i915 0000:00:02.0: [drm] ERROR Atomic update failure on pipe A (start=470450 end=470451) time 4330 us, min 1073, max 1079, scanline start 982, end 112
[T4 Thg 8 2 14:05:15 2023] i915 0000:00:02.0: [drm] ERROR Atomic update failure on pipe A (start=470496 end=470497) time 3497 us, min 1073, max 1079, scanline start 843, end 1080
[T4 Thg 8 2 14:05:16 2023] i915 0000:00:02.0: [drm] ERROR Atomic update failure on pipe A (start=470534 end=470535) time 4839 us, min 1073, max 1079, scanline start 761, end 1088

I am a newbie firesim,
So I have no idea how to resolve it now.
If anyone run successfully firesim runworkload , Could you kindly recommend a solution and show me your result ?
Thank you !

Expected Behavior

firesim runworkload with none ERROR

Other Information

No response

@nguyensinhton nguyensinhton added the bug Something isn't working label Aug 3, 2023