Strange "freeze" of io_samples data from ADC. #253

Open
Artyrm opened this issue Aug 19, 2021 · 5 comments
Open

Strange "freeze" of io_samples data from ADC. #253

Artyrm opened this issue Aug 19, 2021 · 5 comments

Comments

@Artyrm
Copy link

Artyrm commented Aug 19, 2021

It is very strange and elusive problem. I understand it is hard to investigate even for me, having access to the devices.
But still I wanted to ask - maybe someone will have some ideas about what is happening.

It may be also a hardware problem - since I have it only with XBee SX 868 produced in 2020, and never saw it on earlier versions. Also, it happens more often after I upgraded to the latest firmware (A00A). But even with all those considerations I can't wrap my head around what is happening in Python software. My late issue here isn't connected with that problem, that was only one of measures I tried to implement to fix it.

So, I'm gathering various data via ADC, most notable, temperature. Local device is on Linux, async. sleeping nodes send their samples once in a while. So I have a callback, which checks if IO samples arrived:

def my_data_receive_callback(xbee_packet):
  frame_type = xbee_packet.get_frame_type()
  if (frame_type.name == "IO_DATA_SAMPLE_RX_INDICATOR"):
     address = xbee_packet.x64bit_source_addr.address.hex().upper() #remote.get_64bit_addr().address.hex().upper()
     sample = xbee_packet.io_sample
...

And so on. Usually it worked good. But with those new modules something strange happened.

Temperature may vary slowly, so it was not imediatly apparent to me, that in fact received data just "freeze". I found it out placing node from cold to hot conditions - and temperature doesn't move. I made a received packets counter, and find out that it is stuck as well. Also, I started to look at RAM state, and soon found, that upon that "freeze" RAM began to leak slowly (approx 0.5% of 1GB RAM in a minute, with 30 nodes sending once in half a minute). It happens like, several times a day, with no apparent reason or timing - so it is quite hard to catch. If I restart the software, values immediately catch up to where they should be. I set logging level to "DEBUG", but nothing suspicious or unusual there.

I decided to investigate it further. And to find out state of device = XBeeDevice(PORT, BAUD_RATE) I made device global. And then looks like memory leak ceased, just some minor fluctuations. Packets counter seems to be alive too.

But after a time actual values appears to be frozen again. I thought that something may be wrong with packets handling, but I'm logging each IO_sample raw packet. And when I parsed the log file, it showed me that indeed all those packets were with "frozen" values, and more than that, value may change by bit or two, but nothing near where it should be. So, if I get packets with slowly changing values, perhaps problem is on nodes side? But should I restart the software - values gaps to normal. Moreover, if I close serial port (device.serial_port.close() ) and then reopen it (along with device._packet_listener.run() since it automatically stops with serial port closed), values\packet immediately catch up.

I just thought, upon writing it - could it be that I'm dealing with some deeply buffered "historic" values in fact? Is there a way to check the state of buffers\queues (if any) for that matter in the library?

Anyways, I'd appreciate your thought on:

  1. What may be the reasons of such behavior?
  2. How can I tell from inside the software, when values\packets are "frozen"?
  3. What can be done to "unfreeze", besides resetting serial port (it is ungraceful and some packets would apparently be lost during the process)?
@Artyrm Artyrm changed the title Strange "freese" of io_samples data from ADC. Strange "freeze" of io_samples data from ADC. Aug 19, 2021
@Artyrm
Copy link
Author

Artyrm commented Aug 20, 2021

Little update here.

I tried device.flush_queues(), unfortunately, it didn't help.

@Artyrm
Copy link
Author

Artyrm commented Dec 1, 2021

I can add to this that on 868LP module as receiver this seems to be non-issue.
At the same time SX868 receiving data from 868LP has the same problem.

@TheTripleV
Copy link

Does changing

- remote = self.__try_add_remote_device(read_packet)
+ remote = None

on line 626 of reader.py fix your problem?
https://github.com/digidotcom/xbee-python/blob/master/digi/xbee/reader.py#L626

@Artyrm
Copy link
Author

Artyrm commented Dec 10, 2021

@TheTripleV
Thank you for your reply, I'll definitely give it a try.

@Artyrm
Copy link
Author

Artyrm commented Dec 13, 2021

@TheTripleV unfortunately, it is all the same - freeze, memory leak.

For now even to detect "freeze" state would be of great help.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants