Infeasibility due to positive startup power for multiple startup types #1086

Open
sriharid opened this issue Jan 22, 2024 · 0 comments
Open

Comments

@sriharid
Copy link
Contributor

When multiple startup types are defined, unique_startup_type_constraint_rule() ensures that not more than one of the GenCommitBin_Startup_Type flags is 1 at any point by equating their sum to the binary flag GenCommitBin_Startup. However, there is no such constraint on the power provided by each of the startup types, i.e., GenCommitBin_Provide_Power_Startup_By_ST_MW. This is okay as long as the unit gets committed within the same subproblem in which the start up trajectory begins, in which case the increasing_startup_power_by_st_constraint_rule() ensures that power provided by exactly one startup type becomes positive. However, when the commitment happens in a subsequent subproblem, positive power could be provided for multiple startup types, which then results in an infeasibility at the time of commitment, since the overall startup power (which is the sum of the individual startup powers) needs to be set to 0 at the time of commitment, but that cannot be possible since the startup power can be set to 0 only for that startup type whose GenCommitBin_Startup_Type is set.

Note: Commitment could be forced minimum_up_time hours before the unit becomes unavailable, so this could be a trigger for the infeasibility.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

1 participant