Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

c8 crashes when encountering data:text/javascript;base64 URLs #477

Open
jahorton opened this issue Jun 12, 2023 · 0 comments
Open

c8 crashes when encountering data:text/javascript;base64 URLs #477

jahorton opened this issue Jun 12, 2023 · 0 comments

Comments

@jahorton
Copy link

  • Version: v18.16.0
  • Platform: Microsoft Windows 10 Home / 10.0.19045 Build 19045
    • via MINGW64_NT-10.0-19045 User-PC 3.4.6.x86_64 2023-05-18 20:39 UTC x86_64 Msys
TypeError [ERR_INVALID_URL_SCHEME]: The URL must be of scheme file
    at new NodeError (node:internal/errors:399:5)
    at fileURLToPath (node:internal/url:1225:11)
    at Report._normalizeSourceMapCache (C:\keymanapp\keyman\node_modules\c8\lib\report.js:314:29)
    at Report._getMergedProcessCov (C:\keymanapp\keyman\node_modules\c8\lib\report.js:183:51)
    at Report.getCoverageMapFromAllCoverageFiles (C:\keymanapp\keyman\node_modules\c8\lib\report.js:92:31)
    at Report.run (C:\keymanapp\keyman\node_modules\c8\lib\report.js:72:31)
    at exports.outputReport (C:\keymanapp\keyman\node_modules\c8\lib\commands\report.js:39:16)
    at C:\keymanapp\keyman\node_modules\c8\bin\c8.js:39:15
    at ChildProcess.<anonymous> (C:\keymanapp\keyman\node_modules\foreground-child\index.js:88:20)
    at ChildProcess.emit (node:events:513:28)

Context: I have a project that embeds a Worker's code within its source. When live, the project constructs a data URL (on Node) or a Blob (in the DOM) for use to initialize that Worker. We're able to use this setup to run integration tests with the worker headlessly on Node. However, when running those automated tests under c8, the error above occurs.

Noting the method mentioned in the stack log above...

c8/lib/report.js

Lines 389 to 395 in f8ee1ff

_normalizeSourceMapCache (v8SourceMapCache) {
const cache = {}
for (const fileURL of Object.keys(v8SourceMapCache)) {
cache[pathToFileURL(fileURLToPath(fileURL)).href] = v8SourceMapCache[fileURL]
}
return cache
}

I have confirmed that the following prevents a c8 crash:

    for (const fileURL of Object.keys(v8SourceMapCache)) {
        if(fileURL.startsWith("data:text/javascript")) {
            cache[fileURL] = fileURL
        } else {
            cache[pathToFileURL(fileURLToPath(fileURL)).href] = v8SourceMapCache[fileURL]
        }
    }

That said, I'm not well-versed enough in c8 architecture to know if this would cause undesired collateral effects.

If nothing else, it does cause VS Code to near-instantly hang when loading a temp-file with the resulting base64 JSON-object key, likely because of the difficulty of parsing it in the middle of lots of other JSON. I don't want the 'file' in my reports... but I imagine it would cause the report table to practically explode if not handled properly in some manner.

As the report stat calculation itself doesn't fall over, it may be wise to add a mapping structure (when necessary) for data URLs. Perhaps... give them a nice short-hand version in the report and the JSON keys, but maintain the longer-form for cache comparisons... and to provide enough identifying information about which data URL is being reported if it actually shows up in the report?

Also interesting:

  • the error does not occur when running under VS Code's "JavaScript Debug Terminal" (for Node.js-based debugging).
    • It appears that the file's coverage data somehow isn't generated / passed to c8 when run this way for some reason?
  • adding a post-test-suite timeout to all test suites does not work around the error.