Values Wattage and Load in Circuit Monitor are 400 (20*20) times smaller than Multimeter Block.
I think there is error in: electrodynamics.common.tile.electricitygrid.TileCircuitMonitor::getMonitoredValue():
case 0 -> network.getActiveTransmitted() / 20.0;
but in electrodynamics.client.render.tile.RenderMultimeterBlock::render():
multimeter.joules.get() * 20.0
The text was updated successfully, but these errors were encountered:
Values Wattage and Load in Circuit Monitor are 400 (20*20) times smaller than Multimeter Block.
I think there is error in:
electrodynamics.common.tile.electricitygrid.TileCircuitMonitor::getMonitoredValue()
:case 0 -> network.getActiveTransmitted() / 20.0;
but in
electrodynamics.client.render.tile.RenderMultimeterBlock::render()
:multimeter.joules.get() * 20.0