Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

create TOF-equivalent sensitivity image when using non-TOF norm #1398

Open
KrisThielemans opened this issue Mar 11, 2024 · 1 comment
Open

Comments

@KrisThielemans
Copy link
Collaborator

At present, we either do TOF or non-TOF backprojection. However, the former is slow and the latter is not quite accurate at the edges of the LOR. @NikEfth and I think this can be relatively easily solved by adding a 3rd option where we do a backprojection with 1 very large TOF bin. In principle, the TOF kernel should adjust.

Relevant code modification is probably mostly here and a few occurences of use_tofsens.

@KrisThielemans KrisThielemans self-assigned this Mar 11, 2024
@KrisThielemans KrisThielemans added this to To do in TOF improvements and fixes via automation Mar 11, 2024
@NikEfth
Copy link
Collaborator

NikEfth commented Mar 26, 2024

This is wip, and I have not committed everything. The work is in the modifications_for_PSMR20204 branch.

@NikEfth NikEfth self-assigned this Mar 26, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Development

No branches or pull requests

2 participants