Unable to find an appropriate device to wire to #272

Open
ebach23 opened this issue May 9, 2024 · 6 comments
Open

Unable to find an appropriate device to wire to #272

ebach23 opened this issue May 9, 2024 · 6 comments
Labels
question Further information is requested

Comments

@ebach23
Copy link

ebach23 commented May 9, 2024

I posted this on the main spike interface issue page and was suggested the following:
"Looks like we don't have wiring to RHD2216 yet. I would open this issue on the probeinterface repo so that it can be put on the todo list over there. We have tools to allow you to do it manually if you want help with that and if you get that working then you can actually share the mapping with us and we can include it in probeinterface in the future."

We recently switched from a Cambridge Neurotech 64 channel probe to a Cambridge Neurotech 16 channel probe that uses an omnetics adapter to connect to our Intan 16 channel headstage. We are trying to analyze a group of our data obtained with this set-up but are not able to wire to any of the devices that are listed as an option for these probes.
Our probes are: ASSY-1-P-2 - cambridgeneurotech - 16ch - 1shanks
The device options made available are:
['H32>RHD2132',
'ASSY-156>RHD2164',
'ASSY-116>RHD2132',
'ASSY-77>Adpt.A64-Om32_2x-sm-NN>RHD2164',
'ASSY-77>Adpt.A64-Om32_2x-sm-NN>two_RHD2132',
'cambridgeneurotech_mini-amp-64']

All of these appear to be 32 to channel or 64 channel which then read the error: "AssertionError: chan_indices 32 != contact count 16"
Can you help us identify how we can fix this problem?

@alejoe91
Copy link
Member

alejoe91 commented May 9, 2024

Hi! Do you have a channel map for your setup?

@alejoe91 alejoe91 added the question Further information is requested label May 9, 2024
@ebach23
Copy link
Author

ebach23 commented May 9, 2024 via email

@alejoe91
Copy link
Member

alejoe91 commented May 9, 2024

I cannot see the images because I think you replied to the email. Can you reply to the issue instead?

@ebach23
Copy link
Author

ebach23 commented May 9, 2024

Sorry about that. Hopefully it will work now…
image
image

@zm711
Copy link
Contributor

zm711 commented May 17, 2024

@ebach23, could you also share the headstage info you're using. We need to see the final connectors on the other side of the omnetics!

@ebach23
Copy link
Author

ebach23 commented May 22, 2024

Oops, I missed your question until now. The headstage we are using is an Intan C3334 | RHD 16-channel headstage18-pin Omnetics electrode connector