Comments
I’ve got this too. Using BT with Tuya valves. Any restart of HA (update, power cycle etc) results in the BT instances becoming unavailable even though the Tuya valves still work within the Tuya integration. The workaround noted by @soeoeb works for me - I manually reconfigure each BT instance making a small change to the sensitivity threshold, and it comes back on line. Weirdly, reloading BT doesn’t help. It needs to be reconfigured and there needs to be an actual change to the configuration, however small. Nor does hitting configure and then saving without a change help. |
Facing the same issue, but not only on BT, also on versatile_thermostat. Probably something changed recently in climate or loading in core? |
Same Situation here with my two Tuya valves (SALCAR TRV801W). The Rademacher Valves are working. |
for me the same, also with BT Version 1.5.0 |
For me it's the same. I can solve the problem temporarily, if I reconfigure the component with a new value, e.g. increase "the outdoor temperature when the thermostat turns off" and it keeps available until the temperature sensor is unavailable for a short time or until a reboot. |
This could also be useful to look at. I kicked out all the window switches in the BT that where not working anymore. After this, they work again, just without the window detection. After the debugging, I hope I can switch them back ;-) #1333 |
i had too many problems with 1.5.0 also with 1.5.1
i went back to 1.4.0 , then recreated all devices => all problems gone |
I had the same problem with my Bosch BTH-RA thermostats. I saw that in Z2M under Details the system mode for my devices was not set. After I clicked on one of the available options, my devices were available again in BT. |
Thanks for the tip, that's exactly it, BT hasn't been working for days (since I noticed it). Now it works again. Nevertheless, I will test and set up the “Advanced Heating Control” blueprint soon. A BT has already failed one or two times, the first time it was due to an unavailable external sensor because there was no connection and now I think after the update to HA 24.5.x or a restart. |
for its not working like this, so thats maybe only a workaround for some devices! |
Workaround for my Tuya devices TRV SALCAR TRV801W)
Hardware Raspberry PI 4 I have inserted some lines of code to the module /homeassistant/custom_components/better_thermostat/utils/controlling.py after line 213. Now the Tuya TRV are active again even after a restart of HA.
Background: The devices return an error when the HVAC mode is set to HEAT. Therefore, the workaround for this case is to set the HVAC mode to HEAT_COOL. |
@UweTo looks good. Is it possible to write down some of the code before and after your workaround! If i go to line 213, there is still the "_logger.debug" -line! So with some additional lines i have a better overview:) |
workaround with additional lines:
|
Model name of your Devices: ME167 Wireless Smart Radiator Thermostat (tuya)
Output from Home Assistant Developer Tools state e.g.:
State of climate.bt_test: unavailable
Description
Every time I restart HA or reboot the system, my BT devices stop working (reporting "not available"). The real thermostats keep working just fine. After "making my devices stop working" I am getting a error message in HA system protocols:
In some cases I was able to "fix" the devices by reconfiguring the integration entry and changing values like tolerance on p. 1 or auto heat swap / alternative off mode on p. 2 of the config form, restarting HA and then repeat the reconfiguration process:
But most of the times, the only way to "fix" BT was to completely delete all integration entities, remove the HACCS integration, reinstalling BT and reconfiguring devices (restarting HA after every step). Why my workaround worked some time and why it didn't any other time is beyond me.
Steps to Reproduce
Expected behavior:
For my set up BT devices to remain available.
Actual behavior:
BT devices not responding.
Versions
HA versions:
Core: 2024.3.1
Supervisor: 2024.03.0
Operating System: 12.1
Frontend: 20240307.0
BT version:
Better Thermostat Firmware: 1.4.0
Additional Information
Don't know if that's of any help but this is the output of HA dev tools regarding the entity state when the entity is available:
State of climate.bt_test
When trying to investigate what's happening I stumbled upon two reoccurring errors in the HA protocol that happen when BT devices are working/available.
The text was updated successfully, but these errors were encountered: