Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Stress artifacts in parallel mechanics solves #3119

Open
ryar9534 opened this issue May 10, 2024 · 0 comments
Open

Stress artifacts in parallel mechanics solves #3119

ryar9534 opened this issue May 10, 2024 · 0 comments
Assignees
Labels
type: bug Something isn't working type: new A new issue has been created and requires attention

Comments

@ryar9534
Copy link
Contributor

Describe the bug
I am seeing some odd stress behavior in my poromechanical initialization of HI24L. In particular, there were some oscillations in stress on the boundaries between MPI ranks. On further testing I have narrowed it down to the mechanics solver, which seems to exhibit the same behavior. Here is an xml for a mechanics only sim on the underburden of HI24L:
HI24L_mech_debug.zip

I ran with 1 rank (left) and 4 ranks (right), and slightly different results are obtained:

Screenshot 2024-05-10 093737

And the differences seem to line up with the MPI rank boundaries:

image

I have yet to see this effect on any other mesh, so perhaps its HI specific.

@ryar9534 ryar9534 added type: bug Something isn't working type: new A new issue has been created and requires attention labels May 10, 2024
@ryar9534 ryar9534 self-assigned this May 10, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment