magnetometer temperature enabled causes datalogger lockup - https://www.sparkfun.com/products/20594 #29

Open
mvschaefer opened this issue Mar 25, 2024 · 3 comments

Comments

@mvschaefer
Copy link

when the magnetometer has the temperature output enabled, the datalogger locks up after ~a few hundred samples

@mvschaefer
Copy link
Author

Version: 01.01.01 - build 0000f4

@gigapod
Copy link
Member

gigapod commented Mar 26, 2024

Can you try the preview release here: https://github.com/sparkfun/SparkFun_DataLogger/releases/tag/v01.01.99

@mvschaefer
Copy link
Author

initial testing of: Version: 01.01.99 Version 1.2 Preview - build 00013b

confirms both die temperatures (accel/gyro + mag) log to file without causing crash