How to do NTP sync ? #15

Open
C1Ron opened this issue Dec 11, 2023 · 9 comments
Open

How to do NTP sync ? #15

C1Ron opened this issue Dec 11, 2023 · 9 comments

Comments

@C1Ron
Copy link

C1Ron commented Dec 11, 2023

I'm using version 01.01.01 - build 0000f4.
I've enabled NTP with servers: pool.ntp.org and time.nist.gov, and I'm connected to wifi, but the main clock quickly falls behind.
To resync the datetime, I've tried to restart device, disconnect/reconnect wifi, disable/re-enable NTP...
Nothing works.

I'm guessing the NTP won't resync unless the timedelta is above a certain threshold ?
How can I resync the clock ?

@gigapod
Copy link
Member

gigapod commented Dec 12, 2023

HI @C1Ron -

We're basically using the default setup provided by the ESP32 API and following what the ESP32 Arduino implementation does.

Enabling/disabling the NTP option/service stops and starts it internally.

How far does it drift and how long to reach the drift point. And are you just comparing to other NTP synched devices?

Also, any other devices connected to the DataLogger? We'll try to reproduce this and find a solution.

-Kirk

@C1Ron
Copy link
Author

C1Ron commented Dec 14, 2023

Hi @gigapod

Last time I used the datalogger, it synchronized the clock when powering up in the morning, but then drifted by more than 10 sec behind in less than 5 hours later.

I'm comparing the clock to several other sources, e.g. to the time at http://time.is, and also to ntp requests from "europe.pool.ntp.org" from a Windows PC.

There are no devices connected.

Thanks :)

EDIT: note that the clock drifts less when not interfering the logging process. Today I was able to update the clock from zero unix time (1st jan 1970) and let the logger run for 30 minutes with ~ 1 sec drift. However, when going into the system settings trying to disable/enable the NTP and the WiFi, then it suddenly lagged by ~5 sec...

@gigapod
Copy link
Member

gigapod commented Dec 15, 2023

Hi @C1Ron -

Hmm, I've had several of these devices just running, and the time is staying synched. Are you getting time output from log output or just when you bring up the settings menu (which shows time)?

When getting the data to log the system first grabs the timestamp, then loops over the connected devices to grab the latest data values for output. But this shouldn't cause any issues on the systems time value.

We'll keep trying to reproduce on our end.

-Kirk

@C1Ron
Copy link
Author

C1Ron commented Jan 10, 2024

Hi @gigapod

For checking time sync I'm watching the log output in the serial console using timestamps.

For reproducing a time lag, please start and stop the logging a few times, and make some changes in the settings. You'll quickly find that the timestamp lags by several seconds.

It would be really nice if you added a command for resyncing the clock. Perhaps the device won't resync unless the time-delta is above some threshold value. I purchased the IMU to measure angular displacement of a hanging load and need the timestamp to match NTP time as closely as possible, with no more error than a second.

Thanks
Ronny

@gigapod
Copy link
Member

gigapod commented Jan 17, 2024

Hi @C1Ron,

Thanks for the additional updates on reproducing the error. We haven't seen it yet and have let several devices run over extending periods.

I wouldn't expect the clock to drift by so much time.

We are using the standard ESP functionality to update the clock via NTP. Additionally, our framework will synch the system and dependent clocks by a user set value - this is in the Clock settings of DataLogger. Key settings:

Reference Clock - This would be the NTP clock/system
Update Interval - Every "N" minutes, the system will grab epoch ticks from the reference clock, and set that value on the system clocks
Dependent Interval - If other clocks are connected to the system - say an RTC board - this is the time period between when the dependent clocks are update using the epoch value of the system.

While we continue to look at this issue - I'll see if we can also add a user driven clock synch command. The next release includes a command system for the serial console that skips the menu system to enter fast commands - a Time Sync command could be added here.

@C1Ron
Copy link
Author

C1Ron commented Jan 24, 2024

Thanks, it would be nice to get a user-driven synch command in the next release.

Today I'm not able to do NTP sync, at all. Even though the timestamp on the datalogger serial output says 31-12-1970 18:26:10.

PS I know that the wifi is connected because I just OTA updated the firmware and I've disabled/enabled the NTP, which produces [I] NTP startup [5 secs] ..... enabled.

The Update Interval is set to 1, so it should be updated after one minute, but unfortunately it doesn't.

@gigapod
Copy link
Member

gigapod commented Jan 24, 2024

Hi @C1Ron ,

This is strange - Our latest take on this issue is that the clock on your board is defective - normally, the NTP sync happens every 60 minutes (default internally on the ESP32). We might need to send you another board for testing - but we want to check one more item.

For the current issue you are seeing - if you disable NTP and then re-enable it, does the clock synch up correctly ?

@C1Ron
Copy link
Author

C1Ron commented Jan 24, 2024 via email

@gigapod
Copy link
Member

gigapod commented Mar 15, 2024

Did you ever get a replacement board to test?

If not - send me an email kirk.benell at sparkfun.com and I'll get a couple sent to you for testing....