Could not find associated Limo file (LIMO EEG) #714

Open
naoqo opened this issue Dec 23, 2023 · 2 comments
Open

Could not find associated Limo file (LIMO EEG) #714

naoqo opened this issue Dec 23, 2023 · 2 comments

Comments

@naoqo
Copy link

naoqo commented Dec 23, 2023

Description

I have completed a first level (subject) analysis using EEGLAB plugin LIMO EEG.
But when I try to carry out 2nd level analysis, matlab returns following errors.

This error happens after I selected the text file which contains the directries of beta files for each participants.
The beta file looks like successfuly created after the 1st level analysis.
The execution leaves empty folders with names of seleceted analysis at 2nd level.

I tried all the inference analysis listed in GUI but they all returns the same error message.
In my study design, the independent variable contains 2 categorical values (S-1, S-2, plus constant).
The data include 2 groups of participants which differ in number.

I'm not sure if this is a bug or just an error due to my data.
But I'd greately appreciate your could provide any assistance with fixing this issue.

Thanks,
Naoko

[Description of the bug]
Warning: could not find associated LIMO file
inputdlg2() - inputdlg function clone with coloring and help for
eeglab().

Usage:
>> Answer = inputdlg2(Prompt,Title,LineNo,DefAns,funcname);

Inputs:
Same as inputdlg. Using the optional additional funcname parameter
the function will create a help button. The help message will be
displayed using the pophelp() function.

Output:
Same as inputdlg

Note: The advantage of this function is that the color of the window
can be changed and that it displays an help button. Edit
supergui to change window options. Also the parameter LineNo
can only be one.

Author: Arnaud Delorme, CNL / Salk Institute, La Jolla, 11 August 2002

See also: supergui(), inputgui()

Output argument "result" (and possibly others) not assigned a value in the execution with "inputdlg2" function.

Error in limo_inputdlg (line 4)
res = inputdlg2(varargin{:});

Error in limo_random_select>get_beta_indices (line 2296)
param = eval( [ '[' cell2mat(limo_inputdlg('which parameters to test e.g [1:3]','parameters option')) ']' ]);

Error in limo_random_select>check_files (line 2359)
[parameters,betas] = get_beta_indices(selectmode, fullfile(Paths{1}, Names{1}));

Error in limo_random_select (line 195)
parameters = check_files(Paths, Names,1);

Error in limo_random_effect>One_Sample_t_test_Callback (line 194)
limo_random_select('one sample t-test',handles.chan_file,'nboot',handles.b,'tfce',handles.tfce,'type','Channels');

Error in gui_mainfcn (line 95)
feval(varargin{:});

Error in limo_random_effect (line 36)
gui_mainfcn(gui_State, varargin{:});

Error in matlab.graphics.internal.figfile.FigFile/read>@(hObject,eventdata)limo_random_effect('One_Sample_t_test_Callback',hObject,eventdata,guidata(hObject))

Error while evaluating UIControl Callback.


#### Steps to Reproduce

I followed workflow recommended in LIMO eeg tutorials and paper which explains how to use limo from bids formated study data.

https://www.frontiersin.org/articles/10.3389/fnins.2020.610388/full

https://github.com/LIMO-EEG-Toolbox/limo_meeg/wiki/2.-One-way-repeated-measures-ANOVA-(Famous,-Unfamiliar,-Scrambled-faces-as-conditions

(After 1st level analysis)

  1. Study --> Linear modeling of EEG data
  2. 2nd level analysis (Opens the gui)
  3. Select ANOVA/ANCOVA, paired t-test, etc
  4. Select Beta file directly from pop-up menu
  5. Error is returned

#### Versions
OS version [Windows 11 pro]
Matlab version [2023a]
EEGLAB version [2022.0]
@arnodelorme
Copy link
Collaborator

@CPernet any comment on this LIMO problem?

@CPernet
Copy link
Collaborator

CPernet commented Feb 8, 2024

Hi Naoko,

Which version of LIMO are you using? v3.4 is the stable version.

If you use the version that comes with EEGLAB plug-in manager (v4), it as been updated a lot as the new GUI generates lots of errors -- most are now fixed here: https://github.com/LIMO-EEG-Toolbox/limo_tools/tree/master. I believe I have seen that error before and fixed it. If that the case that you use the one from the plug-in manager (ie v4) please use the github version and let me know what is happening. If the error subsist, I'll fix it.

thanks
cyril

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment