Compare foundry measurements with model performances #605

Closed
dwarning opened this issue Feb 21, 2024 · 5 comments
Closed

Compare foundry measurements with model performances #605

dwarning opened this issue Feb 21, 2024 · 5 comments

Comments

@dwarning
Copy link

I use s-parameter files to compare foundry measurements with model performances. Question is, how can I use s-parameter from different operating points in parametric simulations only in plotting. Tried to put them in one file doesn't work (with and without an empty line between the data blocks). Using for each file an extra 2-port setup? Looks a bit elaborate.

Originally posted by @dwarning in #475 (comment)

@dwarning
Copy link
Author

@ra3xdh : Could you comment please, Thanks.

@ra3xdh
Copy link
Owner

ra3xdh commented Feb 27, 2024

I didn't fully understand what are trying to do. Could you submit a schematic? The s2p implementation for Ngspice is taken froms2spice utiliy: https://groups.io/g/LTspice/topic/75745954?p=Created,,,20,2,0,0 It may have limitations. If the s2p features for Qucs-S+Ngspice are not sufficient you may use Qucs-S+Qucsator. Qucsator has native support of touchstone files.

@dwarning
Copy link
Author

Thanks.
The problem is not to generate or to convert the s-param files. I have them for different operating points each. But I am not able to show them all in compare to the parametric simulation sweep.

Bildschirmfoto vom 2024-02-27 18-22-21

Only one curve (red) from one file is shown here. The other not. I want only show the data - not simulate with them.

I can provide schematic/project, but you have to include IHP model lib.

@onehebe
Copy link
Contributor

onehebe commented Mar 8, 2024

Hi dwarning,
As far as I can see, the standard frequency-based snp file doesn't contains bias/op information.
If multiple blocks of data with different bias/op included in one file, the parser would terminate at the end of first block.
Maybe you can upload your sample snp file.
We will see how to improve the snp parser function then.

@dwarning
Copy link
Author

dwarning commented Mar 8, 2024

Attached are the 3 sp files as shown before in my picture. I greped them from IHP's mdl file.
spar-vbe_078_vcb_025.s2p.txt
spar-vbe_088_vcb_025.s2p.txt
spar-vbe_096_vcb_025.s2p.txt

Repository owner locked and limited conversation to collaborators Jun 2, 2024