User sessions not terminated after activation of 2FA

Moderate
oliverguenther published GHSA-xfp9-qqfj-x28q May 2, 2023

Package

OpenProject

Affected versions

>= 7.4.0

Patched versions

12.5.4

Description

Impact

For OpenProject versions >= 7.4.0, when a user registers and confirms their first two-factor authentication (2FA) device for an account, existing logged in sessions for that user account are not terminated. Likewise, if an administrators creates a mobile phone 2FA device on behalf of a user, their existing sessions are not terminated.

Patches

The issue has been resolved in OpenProject version 12.5.4 by actively terminating sessions of user accounts having registered and confirmed a 2FA device.

Workarounds

As a workaround, users who register the first 2FA device on their account can manually log out to terminate all other active sessions. This is the default behavior of OpenProject but might be disabled through a configuration option. Double check that this option is not overridden if you plan to employ the workaround.

References

Credits

This security issue was responsibly disclosed by Vaishnavi Pardeshi. Thank you for reaching out to us and your help in identifying this issue. If you have a security vulnerability you would like to disclose, please see our statement on security.

Severity

Moderate
4.8
/ 10

CVSS base metrics

Attack vector
Network
Attack complexity
High
Privileges required
Low
User interaction
Required
Scope
Unchanged
Confidentiality
None
Integrity
High
Availability
None
CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N

CVE ID

CVE-2023-31140