Skip to content

Latest commit

 

History

History
59 lines (49 loc) · 11.2 KB

MVD-Database.md

File metadata and controls

59 lines (49 loc) · 11.2 KB

MVD Database

buildingSMART International official Model View Definitions (MVDs) releases are listed here. This includes exchange specifications for IFC2x3 and IFC4, as well as those that have been accepted as international standards or are currently under development via the buildingSMART Standards Process. Software applications may support sending or receiving data supporting any combination of exchanges.

All MVDs listed below are © buildingSMART International Ltd. Written requests should be addressed to: buildingSMART International Limited, Kings House, Station Road, Kings Langley, Hertfordshire, WD4 8LZ, UK. Email contact@buildingsmart.org.

IFC Schema MVD Name Status Documentation Summary
IFC4 ADD2 TC1 IFC4Precast Final Full documentation (zip) Exchange of geometric information between CAD and MES systems for automated production of precast building components.
IFC4.2 Bridge Construction View Draft BRie 2017.10.24 Build and maintain bridges.
IFC4 ADD2 TC1 Reference View Final RV 1.2 HTML RV_1-2.mvdxml Simplified geometric and relational representation of spatial and physical components to reference model information for design coordination between architectural, structural, and building services (MEP) domains
IFC4 ADD2 TC1 Design Transfer View Draft DTV 1.1 Advanced geometric and relational representation of spatial and physical components to enable the transfer of model information from one tool to another. Not a "round-trip" transfer, but a higher fidelity one-way transfer of data and responsibility.
IFC4 ADD2 TC1 Quantity Takeoff View Draft mvdXML Estimate and track construction materials and costs.
IFC4 ADD2 TC1 Energy Analysis View Draft EV Estimate and track energy usage and costs.
IFC4 ADD2 TC1 Product Library View Draft LV 0.1 Manufacturer product information and configurations.
IFC4 LandXML view LandXML MVD 1.2 Basic buildingSMART MVD for LandXML v1.2.
IFC2x3 TC1 Coordination View Final CV 2.0 Spatial and physical components for design coordination between architectural, structural, and building services (MEP) domains
IFC2x3 TC1 Space Boundary Addon View Final SB 1.1 Identification and export of additional Space Boundaries (polygons which define the extents of a space's contact with directly adjacent surfaces [e.g. walls, floors, ceilings] and openings). Can be used for building energy analysis and quantity take-off.
IFC2x3 TC1 Basic FM Handover View Final Diagrams - Documentation Handover of model information from planning and design applications to CAFM and CMMS applications, as well as the handover of model information from construction and commissioning software to CAFM and CMMS applications
IFC2x3 TC1 Structural Analysis View Final SA The structural analysis model, created in a structural design application by a structural engineer to one or many structural analysis applications.
IFC 2x3 Architectural Design to Building Energy Analysis Candidate link This is not a formal bSI MVD
IFC 2x3 Architectural Design to Circulation/Security Analysis Proposal link This is not a formal bSI MVD
IFC 2x3 Architectural Design to Quantity Takeoff for Cost Estimating Candidate link This is not a formal bSI MVD
IFC 2x3 Architectural Design to Spatial Program Validation Candidate link This is not a formal bSI MVD
IFC 2x3 Concept Design BIM 2010 Official link This is not a formal bSI MVD
IFC 2x3 Design to Code Compliance Checking (ICC 2006) Proposal link This is not a formal bSI MVD
IFC 2x3 Nordic Energy Analysis (subset of CDB-2010) Candidate link This is not a formal bSI MVD
IFC 2x3 Architectural design to structural design Draft link This is not a formal bSI MVD
IFC 2x3 Architectural design to thermal simulation Proposal link This is not a formal bSI MVD
IFC 2x3 Architectural Programming to Architectural Design Draft link This is not a formal bSI MVD
IFC 2x3 Curtain Wall Design to Energy Analysis Draft link This is not a formal bSI MVD
IFC 2x3 Extended coordination view Idea link This is not a formal bSI MVD
IFC 2x3 Extensibility Idea link This is not a formal bSI MVD
IFC 2x3 Indoor climate simulation to HVAC design Proposal link This is not a formal bSI MVD
IFC 2x3 Landscape design to road design Idea link This is not a formal bSI MVD
IFC 2x3 Masonry Structural Design to Structural Analysis Draft link This is not a formal bSI MVD
IFC 2x3 Modular Bldgs-Arch.Design to Struc.Design Draft link This is not a formal bSI MVD
IFC 2x3 Precast Concrete Exchanges Candidate link This is not a formal bSI MVD
IFC 2x3 Road design to landscape design Idea link This is not a formal bSI MVD
IFC 2x3 Space Requirements and Targets to Thermal Simulation Draft link This is not a formal bSI MVD
IFC 2x3 Structural design to structural analysis Proposal link This is not a formal bSI MVD
IFC 2x3 Structural Design to Structural Detailing (ATC-75) Draft link This is not a formal bSI MVD
IFC 2x3 Wood Structural Design to Structural Analysis Draft link This is not a formal bSI MVD
IFC 2x3 Architectural design to quantity take-off - level 1 Idea link This is not a formal bSI MVD
IFC 2x3 Architectural design to quantity take-off - level 2 Draft link This is not a formal bSI MVD
IFC 2x3 Architectural design to quantity take-off - level 3 Idea link This is not a formal bSI MVD

Copyright  Notice

Copyright © 1996-2021 buildingSMART International Limited. All rights reserved.

Any technical documentation made available by buildingSMART International Limited is the copyrighted work of buildingSMART International Limited and is owned by the buildingSMART International Limited. It may be photocopied, used in software development, or translated into another computer language without prior written consent from buildingSMART International Limited provided that full attribution is given. Prior written consent is required if changes are made to the technical specification.

No Warranty Notice

This material is delivered to you as is and buildingSMART International Limited makes no warranty of any kind with regard to it, including, but not limited to, the implied warranties as to its accuracy or fitness for a particular purpose. Any use of the technical documentation or the information contained therein is at the risk of the user. Documentation may include technical or other inaccuracies or typographical errors. buildingSMART International Limited shall not be liable for errors contained therein or for incidental consequential damages in connection with the furnishing, performance or use of the material. The information contained in this document is subject to change without notice |