You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I recently purchased a queen bee pro with the
xpro v5 controller. I have installed the latest firmware, cncjs software and I'm at the point where I would configure my axis'.
I've opened The serial port and I am getting a check door message.
Reffering back to the manual. I see that there is jumpers in the controller. I have move them in order of the diagram. But still I get the check door msg.
What an I missing here?
The text was updated successfully, but these errors were encountered:
Please some news? I have the same problem.
Windows 10
driver silabser.sys ver 11.3.0.176
CNCjs 1.10.3
COM4 Baud rate 115200 on CNCjs and system settings
message from controller
ets Jun 8 2016 00:22:57
rst:0x1 (POWERON_RESET),boot:0x13 (SPI_FAST_FLASH_BOOT)
configsip: 0, SPIWP:0xee
clk_drv:0x00,q_drv:0x00,d_drv:0x00,cs0_drv:0x00,hd_drv:0x00,wp_drv:0x00
mode:DIO, clock div:1
load:0x3fff0018,len:4
load:0x3fff001c,len:1216
ho 0 tail 12 room 4
load:0x40078000,len:9720
ho 0 tail 12 room 4
load:0x40080400,len:6352
entry 0x400806b8
[MSG:Grbl_ESP32 Ver 1.3a Date 20201022]
[MSG:Compiled with ESP32 SDK:v3.2.3-14-gd3e562907]
[MSG:Using machine:CNC_xPRO_V5_XYYZ]
[MSG:Axis count 3]
[MSG:RMT Steps]
[MSG:Init Motors]
[MSG:TMCStepper Library Ver. 0x000701]
[MSG:X Axis Trinamic TMC5160 Step:GPIO(12) Dir:GPIO(14) CS:GPIO(17) Disable:None Index:1 Limits(0.000,300.000)]
[MSG:X Axis Trinamic driver test passed]
[MSG:Y Axis Trinamic TMC5160 Step:GPIO(27) Dir:GPIO(26) CS:GPIO(17) Disable:None Index:2 Limits(0.000,300.000)]
[MSG:Y Axis Trinamic driver test passed]
[MSG:Y2 Axis Trinamic TMC5160 Step:GPIO(33) Dir:GPIO(32) CS:GPIO(17) Disable:None Index:3 Limits(0.000,300.000)]
[MSG:Y2 Axis Trinamic driver test passed]
[MSG:Z Axis Trinamic TMC5160 Step:GPIO(15) Dir:GPIO(2) CS:GPIO(17) Disable:None Index:4 Limits(-300.000,0.000)]
[MSG:Z Axis Trinamic driver test passed]
[MSG:PWM spindle Output:GPIO(25), Enbl:GPIO(4), Dir:None, Freq:5000Hz, Res:13bits]
[MSG:Local access point CNC_xPRO_V5 started, 192.168.0.1]
[MSG:Captive Portal Started]
[MSG:HTTP Started]
[MSG:TELNET Started 23]
[MSG:Flood coolant on pin GPIO(21)]
[MSG:Mist coolant on pin GPIO(21)]
[MSG:X Axis limit switch on pin GPIO(35)]
[MSG:Y Axis limit switch on pin GPIO(34)]
[MSG:Z Axis limit switch on pin GPIO(39)]
[MSG:Probe on pin GPIO(22)]
Grbl 1.3a ['$' for help]
[MSG:Check door]
I recently purchased a queen bee pro with the
xpro v5 controller. I have installed the latest firmware, cncjs software and I'm at the point where I would configure my axis'.
I've opened The serial port and I am getting a check door message.
Reffering back to the manual. I see that there is jumpers in the controller. I have move them in order of the diagram. But still I get the check door msg.
What an I missing here?
The text was updated successfully, but these errors were encountered: