Skip to content
This repository has been archived by the owner on Dec 16, 2023. It is now read-only.

Improved pressure drop model across stenosis #73

Open
pjnair7 opened this issue Jul 30, 2022 · 0 comments
Open

Improved pressure drop model across stenosis #73

pjnair7 opened this issue Jul 30, 2022 · 0 comments

Comments

@pjnair7
Copy link
Collaborator

pjnair7 commented Jul 30, 2022

Current 0D stenosis models only incorporate pressure drop due to turbulent losses at the stenosis (accounted for using the stenosis coefficient). I am planning to add:
A more comprehensive pressure drop model that will account for viscous losses, inertial effect and a continuous component, in addition to the existing turbulent loss. [Ref below]

Itu, L., Sharma, P., Ralovich, K. et al. Non-Invasive Hemodynamic Assessment of Aortic Coarctation: Validation with In Vivo Measurements. Ann Biomed Eng 41, 669–681 (2013). https://doi.org/10.1007/s10439-012-0715-0

Sign up for free to subscribe to this conversation on GitHub. Already have an account? Sign in.
Labels
None yet
Projects
None yet
Development

No branches or pull requests

1 participant