Skip to content

Latest commit

History

History
52 lines (36 loc) 路 2.05 KB

12031.md

File metadata and controls

52 lines (36 loc) 路 2.05 KB
title description addedAt pageClass
Lupus 12031 control via MQTT
Integrate your Lupus 12031 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2019-07-22 20:08:17 UTC
device-page

Lupus 12031

Model 12031
Vendor Lupus
Description Roller shutter
Exposes cover (state, position), linkquality
Picture Lupus 12031

Options

How to use device type specific configuration

  • invert_cover: Inverts the cover position, false: open=100,close=0, true: open=0,close=100 (default false). The value must be true or false

Exposes

Cover

The current state of this cover is in the published state under the state property (value is OPEN or CLOSE). To control this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "OPEN"}, {"state": "CLOSE"}, {"state": "STOP"}. To read the current state of this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}. To change the position publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"position": VALUE} where VALUE is a number between 0 and 100.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.