Allow flexibility for multiple Attic/Foundation elements #1703

Open
shorowit opened this issue May 2, 2024 · 0 comments
Open

Allow flexibility for multiple Attic/Foundation elements #1703

shorowit opened this issue May 2, 2024 · 0 comments
Assignees
Labels
enhancement New feature or request
Milestone

Comments

@shorowit
Copy link
Contributor

shorowit commented May 2, 2024

A user HPXML had two unvented Attic elements, both with WithinInfiltrationVolume=true. That kind of input is technically sufficient to run EnergyPlus, but our Schematron check disallows multiple WithinInfiltrationVolume elements in case they have different values. Can we improve the Schematron check? If it's not possible to do through Schematron, we can move the error-checking to the ruby measure instead.

Also look at the SkirtPresent and VentilationRate elements, they probably have the same limitation.

@shorowit shorowit added the enhancement New feature or request label May 2, 2024
@shorowit shorowit added this to the 1.8.0 milestone May 2, 2024
@shorowit shorowit self-assigned this May 2, 2024
@shorowit shorowit modified the milestones: 1.8.0, 1.9.0 May 7, 2024