Inconsistent use of heating capacity retention for 2-speed and var-speed HPs #1624

Open
shorowit opened this issue Feb 21, 2024 · 1 comment
Assignees
Labels
bug Something isn't working
Milestone

Comments

@shorowit
Copy link
Contributor

When the user specifies a heating capacity retention in their HPXML file, we use it for both speeds in the 2-speed model but only use it for max speed in the variable-speed model (and continue to use the default for min speed). Seems like we should use it for both speeds in both models, or only max speed in both models?

@shorowit shorowit added the bug Something isn't working label Feb 21, 2024
@shorowit shorowit added this to the 1.8.0 milestone Feb 21, 2024
@shorowit
Copy link
Contributor Author

shorowit commented Mar 5, 2024

@jonwinkler's initial reaction is to just modify the maximum speed curve.

@shorowit shorowit self-assigned this Mar 29, 2024
@shorowit shorowit modified the milestones: 1.8.0, 1.9.0 May 16, 2024