Releases: NREL/OpenStudio-ERI
OpenStudio-ERI v1.4.4
OpenStudio-ERI version 1.4.4 has been released. The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
Two packages are available, a minimal zip with a handful of weather files and a full zip with all US TMY3 weather files. OpenStudio-ERI v1.4.4 uses OpenStudio v3.4.0, EnergyPlus v22.1.0, and a proposed HPXML v4.0. Please visit the OpenStudio-ERI v1.4.4 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
Bugfixes
- Fixes possible simulation error if a slab has an ExposedPerimeter near zero.
OpenStudio-ERI v1.4.3
OpenStudio-ERI version 1.4.3 has been released. The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
Two packages are available, a minimal zip with a handful of weather files and a full zip with all US TMY3 weather files. OpenStudio-ERI v1.4.3 uses OpenStudio v3.4.0, EnergyPlus v22.1.0, and a proposed HPXML v4.0. Please visit the OpenStudio-ERI v1.4.3 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
Bugfixes
- Fixes excessive heat transfer when foundation wall interior insulation does not start from the top of the wall.
OpenStudio-ERI v1.4.2
OpenStudio-ERI version 1.4.2 has been released. The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
Two packages are available, a minimal zip with a handful of weather files and a full zip with all US TMY3 weather files. OpenStudio-ERI v1.4.2 uses OpenStudio v3.4.0, EnergyPlus v22.1.0, and a proposed HPXML v4.0. Please visit the OpenStudio-ERI v1.4.2 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
Bugfixes
- Fixes incorrect ERI calculation when the Rated Home has multiple water heaters.
OpenStudio-ERI v1.4.1
OpenStudio-ERI version 1.4.1 has been released. The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
Two packages are available, a minimal zip with a handful of weather files and full zip with all US TMY3 weather files. OpenStudio-ERI v1.4.1 uses OpenStudio v3.4.0, EnergyPlus v22.1.0, and a proposed HPXML v4.0. Please visit the OpenStudio-ERI v1.4.1 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
Bugfixes
- Fixes possible error when running HERS Auto-Generation tests.
OpenStudio-ERI v1.4.0
OpenStudio-ERI version 1.4.0 has been released. The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
Two packages are available, a minimal zip with a handful of weather files and full zip with all US TMY3 weather files. OpenStudio-ERI v1.4.0 uses OpenStudio v3.4.0, EnergyPlus v22.1.0, and a proposed HPXML v4.0. Please visit the OpenStudio-ERI v1.4.0 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
New Features
- Updates to OpenStudio 3.4.0/EnergyPlus 22.1.
- Updates to OpenStudio-HPXML 1.4.0.
- Implements ANSI/RESNET/ICC Standard 301-2019 Addenda C & D.
ERICalculation/Version
can now be "2019ABC" or "2019ABCD" in the HPXML files.- Adds calculation of CO2e Rating Index and CO2e/NOx/SO2 emissions (annual and hourly).
- Adds support for shared hot water recirculation systems controlled by temperature.
- Breaking change:
/HPXML/Building/Site
is now required withAddress/StateCode
andAddress/ZipCode
child elements.
- Output changes:
- Adds "Energy Use: Total" and "Energy Use: Net" columns to the ERI____Home.csv output files; allows hourly outputs.
- Breaking change: New "End Use: <Fuel>: Heating Heat Pump Backup" output, disaggregated from "End Use: <Fuel>: Heating".
- Breaking change: Deprecates duct leakage to outside exemptions; software tools must provide duct leakage to outside or DSE.
SoftwareInfo/extension/ERICalculation/Version
enumerations "2014ADEGL", "2014ADEG", "2014ADE" are replaced by "2014AEG" and "2014AE". - Breaking change: For CFIS systems, an
extension/VentilationOnlyModeAirflowFraction
input is now required to address duct losses during ventilation only mode. - Allows
AirInfiltrationMeasurement/InfiltrationHeight
as an optional input; if not provided, it is inferred from other inputs as before. - Allows duct leakage to be entered in units of CFM50 as an alternative to CFM25.
- Adds a
--skip-simulation
flag that can be used to just generate the ERI Rated/Reference Home HPXMLs and then stop. - Adds a
--rated-home-only
flag to run only the ERI Rated Home simulation (ERI will not be calculated). - Simplifies ERI Reference Home configuration with respect to HVAC types and number of DSE distribution systems.
Bugfixes
- Fixes opaque door R-value in the Reference Home in IECC climate zone 1.
- Fixes possible NaN result for ERI if, in a very cold climate, the Reference Home has no cooling load.
OpenStudio-ERI v1.3.0
OpenStudio-ERI version 1.3.0 has been released. The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
Two packages are available, a minimal zip with a handful of weather files and full zip with all US TMY3 weather files. OpenStudio-ERI v1.3.0 uses OpenStudio v3.3.0, EnergyPlus v9.6.0, and a proposed HPXML v4.0. Please visit the OpenStudio-ERI v1.3.0 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
New Features
- Updates to OpenStudio 3.3.0/EnergyPlus 9.6.0.
- Breaking change: HVAC grading inputs
FanPowerNotTested
,AirflowNotTested
, andChargeNotTested
are no longer accepted. - Breaking change: Replaces "Unmet Load" outputs with "Unmet Hours".
- Breaking change: Renames "Load: Heating" and "Peak Load: Heating" (and Cooling) outputs to include "Delivered".
- Breaking change: Any heat pump backup heating requires
HeatPump/BackupType="integrated"
to be specified. - Breaking change: HPXML schema version must now be '4.0' (proposed).
- Moves
FoundationWall/Insulation/Layer/extension/DistanceToTopOfInsulation
toFoundationWall/Insulation/Layer/DistanceToTopOfInsulation
. - Moves
FoundationWall/Insulation/Layer/extension/DistanceToBottomOfInsulation
toFoundationWall/Insulation/Layer/DistanceToBottomOfInsulation
. - Moves
Slab/PerimeterInsulationDepth
toSlab/PerimeterInsulation/Layer/InsulationDepth
. - Moves
Slab/UnderSlabInsulationWidth
toSlab/UnderSlabInsulation/Layer/InsulationWidth
. - Moves
Slab/UnderSlabInsulationSpansEntireSlab
toSlab/UnderSlabInsulation/Layer/InsulationSpansEntireSlab
.
- Moves
- Allows modeling PTAC and PTHP HVAC systems.
- Allows additional fuel types for generators.
- Allows non-zero refrigerant charge defect ratios for ground source heat pumps.
- Allows CEER (Combined Energy Efficiency Ratio) efficiency unit for room AC.
- Allows specifying the foundation wall type (e.g., solid concrete, concrete block, wood, etc.).
- Removes error-check for number of bedrooms based on conditioned floor area, per RESNET guidance.
- Introduces a small amount of infiltration for unvented spaces.
ConditionedBuildingVolume
input is no longer needed (and removes error-check forInfiltrationVolume
relative to it).- Improves consistency of installation quality calculations for two/variable-speed air source heat pumps and ground source heat pumps.
Bugfixes
- Improves ground reflectance for window interior shading.
- Improves HVAC fan power for central forced air systems.
- Fixes mechanical ventilation compartmentalization area calculation for SFA/MF homes with surfaces with InteriorAdjacentTo==ExteriorAdjacentTo.
- Negative
DistanceToTopOfInsulation
values are now disallowed. - Fixes workflow errors if a
VentilationFan
has zero airflow rate or zero hours of operation. - Fixes heating/cooling seasons (used for e.g. summer vs winter window shading) for the southern hemisphere.
- Relaxes
Overhangs
DistanceToBottomOfWindow vs DistanceToBottomOfWindow validation when Depth is zero. - Fixes possibility of "Construction R-value ... does not match Assembly R-value" error.
OpenStudio-ERI v1.2.1
OpenStudio-ERI version 1.2.1 has been released. Two packages are available, a minimal zip with a handful of weather files and full zip with all US TMY3 weather files.
The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
OpenStudio-ERI v1.2.1 uses OpenStudio v3.1.0, EnergyPlus v9.4.0, and a proposed HPXML v3.1.
Please visit the OpenStudio-ERI v1.2.1 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
New Features
- Revises shared mechanical ventilation preconditioning control logic to operate less often.
OpenStudio-ERI v1.1.2
OpenStudio-ERI version 1.1.2 has been released. Two packages are available, a minimal zip with a handful of weather files and full zip with all US TMY3 weather files.
The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
OpenStudio-ERI v1.1.2 uses OpenStudio v3.1.0, EnergyPlus v9.4.0, and a proposed HPXML v3.1.
Please visit the OpenStudio-ERI v1.1.2 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
New Features
- Revises shared mechanical ventilation preconditioning control logic to operate less often.
OpenStudio-ERI v1.2.0
OpenStudio-ERI version 1.2.0 has been released. Two packages are available, a minimal zip with a handful of weather files and full zip with all US TMY3 weather files.
The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
OpenStudio-ERI v1.2.0 uses OpenStudio v3.1.0, EnergyPlus v9.4.0, and a proposed HPXML v3.1.
Please visit the OpenStudio-ERI v1.2.0 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
New Features
- Adds ENERGY STAR ERI Target workflow for new construction in accordance with ENERGY STAR Certification System for Homes and Apartments Using an Energy Rating Index-Based Compliance Path.
- Optional
SoftwareInfo/extension/EnergyStarCalculation/Version
(values like "SF_National_3.1"; required if running ENERGY STAR calculation). - Breaking change:
Building/Site/Address/StateCode
(values like "CO" or "FL") now required. - Breaking change: For windows,
Window/PerformanceClass
(values of "residential" or "architectural") now required. - Breaking change: For shared boilers,
HeatingSystem/HeatingCapacity
,HeatingSystem/extension/SharedLoopWatts
, andHeatingSystem/extension/FanCoilWatts
(fan coil only) now required. - Breaking change: For air distribution systems with ducts,
AirDistribution/NumberofReturnRegisters
now required. - Breaking change: For shared recirculation hot water systems,
HotWaterDistribution/extension/SharedRecirculation/PumpPower
now required. - Optional
extension/SharedLoopMotorEfficiency
for shared boilers, chillers, cooling towers, and GSHPs w/ shared loop andextension/SharedRecirculation/MotorEfficiency
for shared recirculation hot water systems.
- Optional
- Breaking change: Heating/cooling component loads no longer calculated by default for faster performance; use
--add-component-loads
argument if desired. - Allows
DuctLeakageMeasurement
&ConditionedFloorAreaServed
to not be specified for ductless fan coil systems; Breaking change:AirDistributionType
is now required for all air distribution systems. - Switches room air conditioner model to use Cutler performance curves.
- Shared systems now preserved in the Rated Home (as opposed to configuring, e.g., the equivalent central AC w/ SEEReq for a chiller).
- Removes limitation that a shared water heater serving a shared laundry room can't also serve dwelling unit fixtures (i.e., FractionDHWLoadServed is no longer required to be zero).
- When Reference/Rated water heater fuels are determined by predominant water/space heating fuels, fossil fuel is now selected in the case of a tie.
- Adds IDs to schematron validation errors/warnings when possible.
Bugfixes
- Prevents a solar hot water system w/ SolarFraction=1.
- Fixes room air conditioner performance curve.
- Fixes heating load fractions for boiler w/ WLHP.
- Water loop heat pumps no longer get added electric backup heating in the Rated Home.
OpenStudio-ERI v1.1.1
OpenStudio-ERI version 1.1.1 has been released. Two packages are available, a minimal zip with a handful of weather files and full zip with all US TMY3 weather files.
The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
OpenStudio-ERI v1.1.1 uses OpenStudio v3.1.0, EnergyPlus v9.4.0, and a proposed HPXML v3.1.
Please visit the OpenStudio-ERI v1.1.1 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
New Features
- Allow
Slab/ExposedPerimeter
to be zero. ClothesDryer/ControlType
is no longer required if 301 version >= 2019A- Moves additional error-checking from the ruby measure to the schematron validator.
- Adds more detail to error messages regarding the wrong data type in the HPXML file.
- Adds error-checking for negative SEEReq results for shared cooling systems.
- Relaxes tolerance for duct leakage to outside warning when ducts solely in conditioned space.
Bugfixes
- Fixes ruby error if elements (e.g.,
SystemIdentifier
) exist without the proper 'id'/'idref' attribute. - Fixes error if boiler/GSHP pump power is zero.
- Fixes possible "Electricity category end uses do not sum to total" error due to boiler pump energy.
- Fixes possible "Construction R-value ... does not match Assembly R-value" error for highly insulated enclosure elements.